Quick start
Warning! Never leave the inflator running unattended in this
mode. It can burst car tyres and other items.
To use your inflator immediately, you can do so without
setting the automatic shut-off feature:
Switch the main power switch (1) to the inflate position
(c, fig E).
To switch between the different units (PSI, BAR or KPA)
press the - & + buttons (21 and 23) together until the
required units are displayed.
Connect the universal valve adaptor (6) and an
accessory, if required, to the item to be inflated, making
sure that the lever (19) of the valve adaptor is in the
down position to lock it in place.
Note: Make sure that the universal valve adaptor is correctly
fitted to the item to be inflated.
To start the inflator press the power button (22) on the
LCD.
When the item is inflated as required or to stop the
inflator at any time press the power button (22) on the
LCD.
Remove the hose from the item and store it on the unit.
Turn the main power switch (1) to the off position (b,
fig. E).
Setting the automatic shut-off pressure (fig.E)
Note: The LCD will only display inflation pressures when the
inflator is being used. Battery status will always be shown.
To switch between the different units (PSI, BAR or
KPA), press - & + buttons (21, 23) together until the
required units are displayed.
Press and hold either of the - & + buttons (21, 23) for
3 seconds until the display flashes.
While the display is flashing press the - or + buttons (21,
23) until the required pressure is displayed.
After 3 seconds the display will flash and return to a
reading of "0.0 PSI / 0.00 BAR / 0 KPA". This is normal.
Connect the universal valve adaptor (6) and an
accessory, if required, to the item to be inflated, making
sure that the lever (19) of the valve adaptor is in the
down position to lock it in place.
Note: Make sure that the universal valve adaptor is correctly
fitted to the item to be inflated.
To start the inflator press the power button (22) on the
LCD.
When the item to be inflated has reached the preset
value the unit will automatically stop.
Note: You may notice the actual pressure reading may drop
after a couple of seconds, this is normal.
To stop the inflator at any time press the power button
on (22) the LCD.
Remove the valve adaptor or accessory from the
inflated item and the 12 Vdc adapter (6) from your
vehicle's 12 Vdc accessory socket.
Turn the main power switch (1) to the off position (b).
Note: If the main power switch is turned off, all settings will
be lost and will need to be re-entered following the
instructions under the heading 'Setting the automatic shut-
off pressure (fig. E)'. This is a safety feature to prevent the
risk of items OVER INFLATING.
Using the inflator as a pressure gauge
Switch the main power switch (1) to the inflate
position (c fig. E).
Connect the universal valve adaptor (6) to the item to be
checked.
The LCD will display the items pressure.
After checking, turn the main power switch (1) off and
return the air hose to the storage location.
Operating the high-volume pump
Note: Do not operate the pump when the vehicle’s engine is
running.
Note: Make sure that your 12 Vdc accessory socket is live.
On some vehicles the accessory socket may only become
live when the ignition key is in the accessory position.
To inflate using the high-volume pump (i.e air mattresses,
rafts, swimming pool floats):
Note: The pump mode DOES NOT have an auto shut-off
feature.
Switch the main power switch(1) to the pump
position (a, fig. E).
Remove the high-volume hose (7) from the storage
channel around the centre of the unit and connect it to
the high-volume pump inflate connection (10) (fig. F).
Needs charging.
Charging.
Fully charged.
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Black Decker ASI500 TH2 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Black Decker ASI500 TH2

Black Decker ASI500 TH2 Bedienungsanleitung - Deutsch, Englisch, Holländisch, Dänisch, Französisch, Italienisch, Portugiesisch, Spanisch, Schwedisch, Norwegisch, Finnisch - 94 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info