473018
4
Zoom out
Zoom in
Vorherige Seite
1/52
Nächste Seite
4
ENGLISH
- Walls covered with metal
- Very humid conditions
- Shielded cables
Before use, always test the tool by detecting a known
pipe or wire.
If in doubt contact a qualified contractor.
Warning! This tool will not detect wires in circuits isolated
from the mains supply, cables operating at direct current (DC)
or wires used for telecommunication or computer systems.
Hidden wires (e.g. wall lights) may not be detected when
switches are in the off position.
Warning! This tool will not detect pipes of any other material
than metal.
Features
1. On/off switch
2. Mode selector switch
3. LED indicators (stud/metal finder)
4. LED indicator (AC wire)
Assembly
Fitting the battery (fig. A)
Depress the release button (5) and slide the battery cover
(6) off the tool.
Connect the battery to the connector. The larger battery
terminal connects to the smaller connector terminal.
Refit the cover and let it click into place.
Use
Selecting the operating mode
Set the mode selector switch (2) to the ‘STUD’ position for
the detection of wooden studs.
Set the mode selector switch (2) to the ‘METAL’ position
for the detection of metal studs, pipes, etc.
Using the stud finder function (fig. B)
You can use this function to find wooden and metal studs
through drywall boards up to 18 mm thick.
Set the mode selector switch (2) to the required position.
Place the tool flat against the wall as shown.
Keep the on/off switch (1) depressed.
The red LED indicator (3) will light up and the buzzer will
sound once while the tool is calibrating. After calibration is
completed:
Slowly slide the tool in a horizontal direction. Make sure
not to tilt or lift the tool.
When the red LED indicator (3) lights up, slow down and
slide the tool further until the buzzer sounds and the top
green LED indicator is on.
This position indicates the one edge of the stud.
Mark this position using the centre of the tool as a
reference point.
Move the unit further until the LED indicators are off.
While still keeping the on/off switch (1) depressed,
move the tool in the opposite direction.
When the red LED indicator (3) lights up, slow down and
slide the tool further until the buzzer sounds and the top
green LED indicator is on.
This position indicates the other edge of the stud.
Mark this position using the centre of the tool as a
reference point.
The centre of the stud is between the two marks.
Using the metal finder function (fig. B)
You can use this function to find metal pipes through drywall
boards up to 18 mm thick.
Set the mode selector switch (2) to the ‘METAL’ position.
Place the tool flat against the wall as shown.
Keep the on/off switch (1) depressed.
The red LED indicator (3) will light up and the buzzer will sound
once while the tool is calibrating. After calibration is completed:
While holding the unit with one hand place your other
hand on the surface close to the area being scanned.
Move the tool slowly and smoothly across the surface,
approaching from different directions.
When the red LED indicator (3) lights up, slow down and
slide the tool further until the buzzer sounds and the top
green LED indicator is on.
This position indicates the location of a metal object.
After detecting the work area repeat the testing
procedure to confirm the operation of the unit.
Using the wire detector function (fig. B)
You can use this function to find live wires through drywall
boards up to 38 mm thick. The function works continuously in
all modes.
Warning! Test the unit on a known AC current before use.
Make sure the unit is away from the area being scanned
and any other AC current source. Static charge may
interfere detection on both sides of the wire, resulting in
limited accuracy.
Keep the on/off switch (1) depressed.
The red LED indicator (4) will light up and the buzzer will sound
once while the tool is calibrating. After calibration is completed:
While holding the unit with one hand place your other
hand on the surface close to the area being scanned.
Move the tool slowly and smoothly across the surface,
approaching from different directions.
When an AC source is located, the red LED indicator (4) will blink.
After detecting the work area repeat the testing
procedure to confirm the operation of the unit.
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Black Decker BDS300 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info