Cleaning
You must clean the device regularly to ensure that it ope-
rates smoothly and hygienically. It should be cleaned and
maintained at regular intervals:
Weekly: clean housing components.
Every 2 to 3 months: change filter cartridge.
Annually: clean device after heating season.
The humidifier can be opened for cleaning with a minimum
of effort and without the aid of tools:
Turn off the device and remove the plug from the
mains.
Lift the upper part of the housing with the power cable
to remove it. Never immerse this in water.
Remove the filter cartridge. Deposits in the air and
water build up and contaminate the filter/evaporator
cartridge while the device is in operation. The white
deposits are caused by limescale and not mould. It is
therefore recommended to replace them approximately
every 2 to 3 months.
Replace the filter cartridge sooner if:
It emits odour.
It is heavily contaminated or there is a lot of limescale
build-up (if your water is particularly hard for example).
Humidification performance is clearly impaired
(if your water is particularly hard for example).
Remove residues from the base of the housing and
clean it. You can use a limescale remover such as
CalcOff to remove limescale and mineral deposits.
Once or twice a year, use a damp cloth to wipe clean
the bottom of the ventilator unit.
Warning
Always clean the humidifier if it has not been
used for more than a week.
Switch the device off and remove the plug from the
mains before carrying out maintenance and after
each use.
Never immerse the device in water (ignoring this
advice may lead to a short circuit). Use only a damp
cloth to clean it, and dry it thoroughly afterwards.
Always remove the plug from the mains beforehand.
Ensure that there is no heavy build-up of dust around
the air intake and air exhaust grilles (fire hazard) and
clean them occasionally with a dry brush or vacuum
cleaner.
Notes on how a humidifier works
The drier the air in a room is, the more moisture is
emitted by the device. The self-regulating principle
between the air in a room and the humidifier prevents
excessive humidity. As such, the relative humidity
varies between approx. 45 and 60 %.
If extra humidity is required for larger rooms,
the humidifier can be placed close to a radiator
(do not exceed 50 °C).
It is recommended to use a humidistat to monitor
humidity.
Humidity is heavily restricted by circulating air (for
example, in rooms with poorly sealed/open windows
or in elevated rooms).
Please note that humidity increases as air temperature
rises and this can cause unwanted condensation in
some areas.
Recommended values
for humidity in living space
Storing the appliance for extended periods
Clean the appliance as described earlier and allow to dry
thoroughly. Preferably store the appliance in its original box,
in a dry place away from high temperatures.
Disposal
Return your worn out unit to your dealer for
proper disposal. You can obtain information on
other ways to dispose of the unit from your local
district or town council.
Warranty
The warranty conditions are defined by our representative
in the country of sale. Please contact your dealer if, despite
strict quality control, your appliance becomes defective. You
must present your original receipt when making a claim
under the warranty.
Technical specifications
Mains voltage 230 V / 50 Hz
Power consumption 8 W
Humidity output 250 g/h
Suitable for rooms up to 50 m
2
/ 125 m
3
Water capacity 3.5 liter
Dimensions 350 x 190 x 255 mm
Weight (empty) 1.6 kg
Operating noise level 31 dB(A)
Spare parts
Spare parts can be obtained from your specialist dealer
and installed in the appliance yourself. Only original manu-
facturers parts may be used. All other repairs must be
carried out by a specialist or customer service. This also
applies to a defective mains cable.
Room temperature Relative Humidity
18 °C 50 %
20 °C 45 %
22 °C 40 %
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Boneco E2641 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info