Installation
www.bora.com
5.6 Gas installation
The gas connection may only be carried out by an
authorised gas fitter in accordance with applicable legal
and local regulations. Comply with local regulations of the
utility companies.
Country Regulation/guidelines
Germany DVGW TRGI 2018 and DVGW-worksheet G 600
Austria ÖVGW-GK-guidelines
Switzerland SvgW Gas Regulations G1
EKAA guideline 6517
Regulations of the Vereinigung Kantonaler
Feuerversicherungen (VKF)
Netherlands
Belgium France
Regulations of standard NBN D 51-003
Regulations and connection requirements of
the gas supply company (G.D.F.) and electricity
supply company (E.D.F)
Tab. 5.5 Country requirements (information supplied without
liability)
5.6.1 Ventilation
This appliance is not connected to a flue gas evacuation
device. It must be positioned and connected in
accordance with the applicable installation conditions.
Suitable ventilation measures must be adhered to in
particular.
Always ensure sufficient ventilation during operation
(of the appliance).
5.6.2 Gas connection
This gas cooking appliance corresponds to device
class 3. It is equipped with a flexible connection hose.
The gas hose must meet the requirements of EN14800.
The installation of a security gas socket in the adjacent
unit is recommended.
The connection of liquid gas (LPG) is performed with
the interconnection of a sealed connection socket
(pipe D: 8 x 1 mm).
The connection to the gas supply is to be created with
flexible and seamless pipes made from stainless steel.
The connection with a security gas socket is to be
created in accordance with DIN 3383 with a maximum
length of 1,500 mm.
The connection bracket and connection pieces must
be equipped with a 1/2 inch external thread in
accordance with the regulatory country requirements
(see table 6.2 Connection bracket).
Connect the appliance as follows:
Set the control knob to the 0 position.
Close the gas supply.
Switch off the main switch/automatic circuit breaker
before connecting the cooktop.
Secure the main switch/automatic circuit breaker
against being switched back on without permission.
Make sure the power to the appliance is disconnected.
Check the gas type and gas pressure of the gas supply
pipe.
Ensure that the appliance is equipped with the correct
nozzle type in order to guarantee a correct burner
flame and safe operation.
Remove the protective cap from the connection tube.
Use a security gas socket to connect this directly to
the connection of the gas cooktop using a permitted
security bracket to prevent any leakage of gas.
Only use the connection permitted in your country.
ISO 228-1/ISO7-1(EN10226): cylindrical/conical
ISO 228-1/ISO 228-1: cylindrical/cylindrical
Connect the appliance to the gas supply pipe.
Tighten all connections so that they are secure.
Check that installation has been carried out correctly.
Check the correct functioning of the stopcock.
Check the tightness of the gas connection by
conducting a leak test.
Ensure that there is no risk of ignition sparks.
Do not use fire or an open flame.
Use suitable testing equipment to check all the
connections between the cooktop and the gas
connection.
When using a leak spray for this process, ensure that
you wet all connections.
Shut off the gas supply if you determine that gas is
escaping and ventilate the room.
Seal the point from which the gas is leaking.
Re-check all connections and the gas connection.
Repeat the leak test until all connections are tight.
Create a leak test record and give this to the user.
Switch on the main switch/automatic circuit breaker.
Put the cooktop into operation (see the Operation
chapter).
Check all the functions of the cooktop extractor and
cooktop are working correctly.
Check the burner flame is working correctly,
particularly when the cooktop extractor is in use.
5.6.3 Changing the gas type
Set the control knob to the 0 position.
Shut off the gas supply to the gas supply pipe.
Switch off the main switch/automatic circuit breaker.
Secure the main switch/automatic circuit breaker
against being switched back on without permission.
Make sure the power to the appliance is disconnected.
25

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bora Pro PKG11 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Bora Pro PKG11

Bora Pro PKG11 Bedienungsanleitung - Deutsch - 44 seiten

Bora Pro PKG11 Bedienungsanleitung - Holländisch - 44 seiten

Bora Pro PKG11 Bedienungsanleitung - Französisch - 48 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info