Installation
www.bora.com
6 Installation
Observe all safety and warning information
(see the Safety chapter).
Follow the enclosed manufacturer‘s information
6.1 General installation information
INFO The power supply cable must be provided by the
customer.
INFO The appliance must not be installed above cooling
devices, dishwashers, stoves, ovens, washing
machines or dryers.
INFO The contact surface of the worktops and wall
sealing strips must be made of a heat-resistant
material (up to approx. 100 °C).
INFO Worktop cut-outs must be moisture-sealed using
suitable means and, where necessary, fitted with
a thermal insulator.
INFO The integrated cooktop extractor must not be
used with other cooktops.
General installation information for cooktops
INFO To ensure that the cooktops perform optimally
at all times, there must be sufficient ventilation
beneath the cooktops.
INFO The performance of the cooktops is affected or
the cooktops overheat if the warm air beneath the
cooktops cannot escape.
INFO If a cooktop overheats, the power is automatically
reduced or the cooktop is switched off completely
(see Overheating protection).
INFO If cable protection (false floor) is planned beneath
the appliance, this must be fitted so it does not
obstruct ventilation.
Make sure that the area below the cooktop has a
sufficient air supply.
6.1.1 Simultaneous operation of the
cooktop extractor in the exhaust air
mode and a fireplace dependent upon
the air supply in the room
INFO The state and regional laws and regulations must
be observed with regard to the exhaust duct
design.
INFO A sufficient air supply must be ensured.
Fireplaces that depend on the air in the room (e.g. gas,
oil, wood or coal-fired heaters, continuous-flow water
heaters, instantaneous water heaters) draw in air from
the room in which they are installed and release the
exhaust fumes into the outside air via an exhaust system
(e.g. chimney).
If the cooktop extractor is used in exhaust mode, it draws
in air from the room in which it is installed as well as from
neighbouring rooms. If there is insufficient air supply, low
pressure will occur. Toxic gases could be drawn out of the
chimney or extraction ducting and back into the room.
Fig. 6.1 Exhaust air installation – not permitted
Fig. 6.2 Exhaust air installation – correct
If simultaneously operating both a fireplace and the
cooktop extractor in the same room, ensure that:
the maximum low pressure is 4 Pa (4 x 10–5 bar);
a safety device (e.g. window contact switch, low
pressure warning device) is used to ensure that a
sufficient supply of fresh air is guaranteed;
the exhaust air is not be ducted into a chimney that
is used for exhaust gases of devices operated with
gas or other combustibles;
the installation is checked and approved by an
authorised certified engineer (e.g. heating
engineer).
INFO If the cooktop extractor is used exclusively in
recirculation mode, operation with an open
fireplace is possible without any additional safety
measures.
25

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bora Puru wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Bora Puru

Bora Puru Bedienungsanleitung - Deutsch - 60 seiten

Bora Puru Bedienungsanleitung - Englisch - 60 seiten

Bora Puru Bedienungsanleitung - Holländisch - 64 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info