Electric spray gun
Read all instructions and product labels. When using
electrical tools, follow all precautions to reduce the risk
of re, electric shock, and other personal injury.
TECHNICAL SPECIFICATIONS 1
OPERATION INSTRUCTIONS 2
IMPORTANT SAFETY INSTRUCTIONS
WARNING!
When using electric appliances, basic pre-
cautions should always be followed, including the fol-
lowing:
Read all the instructions before using the appliance.
To reduce the risk of injury, close supervision is nec-
essary when an appliance is used near children.
• Only use attachments recommended or sold by the
manufacturer.
• To disconnect, turn all controls to the off (“O”) posi-
tion, then remove the plug from outlet.
• Do not unplug by pulling on cord. To unplug, grasp
the plug, not the cord.
Unplug from outlet when not in use and before servic-
ing or cleaning.
Do not point the paint roll or accessories toward your-
self; danger of injury by ejected material.
The unit is not a toy; keep it away from children.
Power cable and power plug must be undamaged.
Replace damaged parts immediately.
Never submerge the unit in liquid!
Do not use hot water for rinsing out and cleaning.
The unit may not be used in workplaces bound by the
explosion-protection regulations.
If the supply cord is damaged, it must be replaced by
the manufacturer or its service agent or a similarly
quali ed person in order to avoid a hazard.
Materials to be processed:
Dilute dispersion paints and latex paints for interior and
exterior walls.
Materials not to be processed:
Paint and lacquers containing solvents and materials
containing heavily abrasive components.
INSTALLATION AND OPERATING
Assemble the paint roll ( gure 1).
Mount deaeration unit, connect hoses ( gure 2): slide
suction hose (B), paint feed hose (A) onto the respec-
tive connection pieces until they stop. Slide on screw
sleeves and tighten.
Before beginning work, cover or tape up the oor, fur-
niture, door frames and other objects. Place the unit
on a suf ciently sized piece of plastic or cardboard.
Stir the paint well and thin up to 10% if necessary
(observe information from manufacturer).
• Submerge suction hose with suction lter ( gure 3)
to the bottom of the paint container and fasten to the
paint container edge with clamp.
Turn the control knob to the “working” position. ( gure
4) The pressure in pipe B will reduce when it exceeds
the set value.
Open dosage valve at handle. Switch unit on ( gure
5). Suction and paint feed hoses and paint roll ll with
paint in appox.2 min. The unit is ready for operation
when the rst drops of paint emerge. Set the paint
feed as required using the dosage valve.
ATTENTION! Air in the suction hose or pump area can
lead to suction and function interruptions. Ensure that
the suction lter is always completely covered with
paint. Re ll paint in a timely manner, set the paint con-
tainer at an angle or prepare a new paint container.
Switch off the unit before moving the suction hose to a
new paint container.
BREAKS DURING WORK
Immediately stop
Press down the button ( gure 6), the paint roll will be
stopped lling with paint until the valve is opened ( gure
7).
Short breaks (up to four hours):
Switch off paint pump and open dosage unit in han-
dle.
Insert paint roll into plastic bag immediately and tie it
up to airtight ( gure 8, A).
Leave suction and air bleed hoses in the paint.
Long breaks (days):
Place paint roll in a bucket of water ( gure 8, B).
Wet the paint surface in the paint container with some
water to prevent a skin from forming.
Used accessories which are already unscrewed are
to be placed into water immediately after use.
CLEANING
Switch off the appliance and scrape off paint roll over
the paint container.
Remove paint roll by snapping it from the roller frame
and clean it thoroughly separately. Detach the seal-
ing cap of the paint roll with a suitable tool. Detach
paint roll and clean all parts in lukewarm water.
Put the suction hose A into a container which is lled
with clean water.
Switch on the appliance and pump water for about 10
minutes. Shut down g6 and open the valve g 7 for
8 times during the pumping. Each closed time should
not less than 15 seconds.
Disconnect the aluminum hose and clean it separate-
ly.
ATTENTION! When storing, always leave the dosage unit
in the handle in the open position (Figure 5).
GB
English
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bort BFP-450N wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info