AGS10-2, AGS10E-2, AGS20-2, AGS50-26 720 811 270 (2015/04)
Table of contents
1 Key to symbols and safety instructions . . . . . . . . . . . . . . . . . . . 2
1.1 Key to symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.2 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . 2
2 Information on the solar pump station . . . . . . . . . . . . . . . . . . . . 3
2.1 Product description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.2 Determined use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.3 Components and technical documentation . . . . . . . . . . . 5
2.4 EC Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . 6
2.5 Scope of Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.6 Other equipment required . . . . . . . . . . . . . . . . . . . . . . . . 6
2.7 Air vent valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3 Regulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4 Installing pipework . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4.1 General information regarding pipework . . . . . . . . . . . . . 7
4.2 Laying pipes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
5 Installing the solar pump station . . . . . . . . . . . . . . . . . . . . . . . . 9
5.1 Layout of the installation space . . . . . . . . . . . . . . . . . . . . 9
5.2 Mounting the solar pump station . . . . . . . . . . . . . . . . . . . 9
5.3 Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.4 Installing the safety assembly . . . . . . . . . . . . . . . . . . . . 10
5.5 Connecting the expansion vessel and pre-cooling
vessel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.6 Connecting pipework and pressure relief valve
discharge pipe to the solar pump station . . . . . . . . . . . 11
5.7 Installing temperature sensors . . . . . . . . . . . . . . . . . . . 12
6 Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
6.1 Use of heat transfer fluid . . . . . . . . . . . . . . . . . . . . . . . . 12
6.2 Purging and filling with a hand pump (air vent on roof) 12
6.3 Setting the flow rate . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
6.4 Completion of work . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
7 Environment / disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
8 Commissioning, inspection and maintenance reports . . . . 18
9 Faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
1 Key to symbols and safety instructions
1.1 Key to symbols
Warnings
The following keywords are defined and can be used in this document:
NOTICE indicates a situation that could result in damage to property
or equipment.
CAUTION indicates a situation that could result in minor to medium
injury.
WARNING indicates a situation that could result in severe injury or
death.
DANGER indicates a situation that will result in severe injury or death.
Important information
Additional symbols
1.2 General safety instructions
Mounting
Installation and maintenance must only be carried out by an approved
contractor.
Please read these instructions carefully.
Never modify components.
Replace faulty parts immediately. Use only original spare parts.
To limit the temperature at the tap to a maximum of 60 °C, install a
DHW mixer.
Only use materials which are glycol resistant and which can withstand
temperatures of up to 150 °C.
Electrical work
Ensure that electrical work is only carried out by authorised
electricians.
Ensure that an isolator compliant with EN 60335-1 for disconnecting
all poles from the power supply is fitted.
If you wish to open the solar pump station:
Disconnect the solar pump station from the power supply.
Warnings in this document are identified by a warning
triangle printed against a grey background.
Keywords at the start of a warning indicate the type and
seriousness of the ensuing risk if measures to prevent
the risk are not taken.
This symbol indicates important information where
there is no risk to people or property.
Symbol Explanation
Step in an action sequence
Cross-reference to another part of the document
List entry
List entry (second level)
Table 1
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch AGS10-2 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info