Installing the solar pump station | 9
6 720 811 270 (2015/04)AGS10-2, AGS10E-2, AGS20-2, AGS50-2
Earthing pipes
Arrange for work to be performed by a competent person.
One earthing clamp must be fitted to both the flow pipe and the return
pipe (at any position).
Connect the earthing clamps to the building's equipotential bonding
strip by means of a standard PVC-sheathed bonding cable (cable to be
sized in accordance with BS7671).
Insulating pipework
Thermally insulate the pipework in the entire solar circuit in
accordance with regulations and best practice.
Insulate outdoor piping with material which is both resistant to UV
light and high temperatures (up to 150 °C).
Insulate indoor piping with material which is resistant to high
temperatures (up to 150 °C).
Protect the insulation against damage from animals if required.
Fig. 11 Minimum requirements of the insulation
5 Installing the solar pump station
5.1 Layout of the installation space
To make it easier to connect the temperature sensors:
Install the solar pump station [2] as close as possible to the solar
cylinder [1].
Allow enough room for a solar expansion vessel [3] and holding
container [4].
Fig. 12 Recommended positioning (measurements in mm)
[1] Solar cylinder
[2] Solar station
[3] Expansion vessel
[4] Drip pan
5.2 Mounting the solar pump station
Use a socket (13 mm) with a 150 mm extension to screw in the screws.
With shorter extensions, the handles and temperature gauges [3] can be
pulled forwards and removed for easier access to the screws.
Single-line solar pump station
Drill hole and fix solar pump station using rawl plug and screw
supplied [1, 2].
Twin-line solar pump station
Drill holes spaced 60 mm apart and fix solar pump station using rawl
plugs and screws supplied [4, 2].
Fig. 13 Mounting the station
[1] Mounting for single-line solar pumping station
[2] Rawl plugs and screws supplied
[3] Thermometer
[4] Mounting for twin-line solar pump station
5.3 Electrical connection
UV
> 150 °C
> 150 °C
6720801165.10-1.ST
7747006489.07.3 ST7747006489.07.3 ST
Observe minimum clearances from the solar pump
station to the collector array of the vacuum tube
collectors ( Chapter 4.2, page 8)
DANGER: Danger to life through electric shock!
Before carrying out work on electrical components,
isolate them from the power supply (230 V AC) (fuse,
circuit breaker) and secure against unintentional
reconnection.
Electrical connections must only be completed by
appropriately qualified engineers subject to local and
national regulations.
NOTICE: Damage through pump running dry!
Do not run the pump until the pipework system has
been filled.
4
1
10
13
150 mm
2
60 mm
3
6720801165.11-2.ST
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch AGS20-2 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info