Commissioning, inspection and maintenance reports | 19
6 720 811 270 (2015/04)AGS10-2, AGS10E-2, AGS20-2, AGS50-2
This Commissioning Checklist is to be completed in full by the competent person who commissioned the Solar Thermal System and
associated equipment as a means of demonstrating compliance with the appropriate Building Regulations and then handed to the customer to
keep for future reference.
Failure to install and commission this equipment to the manufacturer’s instructions may invalidate the warranty but does not affect statutory rights.
SOLAR THERMAL COMMISSIONING CHECKLIST
Customer name: Telephone number:
Address:
Commissioned by (PRINT NAME): Telephone number:
Company name:
Company address:
Commissioning date:
7REHFRPSOHWHGE\WKHFXVWRPHURQUHFHLSWRID%XLOGLQJ5HJXODWLRQV&RPSOLDQFH&HUWL¿FDWH
%XLOGLQJ5HJXODWLRQV1RWL¿FDWLRQ1XPEHULIDSSOLFDEOH
&RQ¿UPDWLRQWKDWUHTXLUHGDUHDVRIWKHLQVWDOODWLRQKDYHEHHQQRWL¿HGWR/RFDO$XWKRULW\%XLOGLQJ&RQWURO/$%&
a). Initials of commissioning engineer
E&RPSHWHQW3HUVRQV6FKHPH&36GHWDLOVRUGHWDLOVRI/$%&GLUHFWQRWLL¿FDWLRQ
&RQ¿UPDWLRQWKDWSDQHOVKDYHEHHQLQVWDOOHGZLWKRXWOHVVHQLQJWKHVWUXFWXUHZHDWKHULQJDQG¿UHUHVLVWDQFHRIWKHURRILQDFFRUGDQFHZLWKWKHUHOHYDQW%XLOGLQJ
Regulations and standards. Initials of commissioning engineer
COLLECTOR DETAILS
Make of collector Model of collector
Serial number of each collector: (if more than 6 collectors please append additional sheet)
i. ii. iii.
iv. v. vi.
INSTALLATION DETAILS
Solar System Operating Pressure bar (cold) Expansion vessel air/nitrogen charge bar (cold)
Expansion or drain back vessel size litres
Operating correctly: Yes 7UHDWHGIRUOHDNVDQGÀXVKHG Yes Filled and purged for air: Yes
6\VWHPKHDWWUDQVIHUÀXLGGHWDLOV
:KDWW\SHPDNHRIKHDWWUDQVIHUÀXLGXVHG" System volume litres
:KDWLVWKHÀXLGPL[:DWHU % Glycol %
Frost protection provided to °C
,VWKHLQVWDOODWLRQLQDKDUGZDWHUDUHDDERYHSSP" Yes No
,I\HVKDVDZDWHUVFDOHUHGXFHUEHHQ¿WWHGRUKDV7PD[EHHQOLPLWHGWRÛ&" Yes No
:KDWW\SHRIVFDOHUHGXFHUKDVEHHQ¿WWHG"
Air purged from solar primary circuit: Yes 3ULPDU\FLUFXLWYDOYHVDQGDLUYHQWVVHWWR¿QDORSHUDWLQJSRVLWLRQV Yes
Pump speed setting recorded: Speed setting 0D[ÀRZUDWH litres/min
Solar primary circuit pressure relief valves tested for correct operation: Yes /RFDWLRQ
'HYLFHIRUOLPLWLQJKRWZDWHUWHPSHUDWXUHRXWOHWVKDVEHHQ¿WWHG Yes N o
Type /RFDWLRQ
All exposed pipework lagged in accordance with regulations using suitably temperature rated materials Yes
)RUXQYHQWHGKRWZDWHUVWRUDJHF\OLQGHUZLOOFRQWUROVVWRSVRODUÀXLGFLUFXODWLRQLQWKHHYHQWRIF\OLQGHURYHUKHDWLQJ" Yes
SOLAR SYSTEM CONTROLS
Make and model of DTC
Temperature sensors checked and operating correctly Yes
Differential Temperature Controller (DTC) settings:
T on °C T off °C
T max °C Other DTC Settings
Thermostat located in back-up heating zone of cylinder Yes No
+DYHRSWLPXPVHWWLQJVIRU+:FRQWUROVEHHQH[SODLQHGWRWKHFXVWRPHU" Yes No
'RHVWKLVLQFOXGH/HJLRQHOOD%DFWHULDSURWHFWLRQVHWWLQJVZLWKEDFNXSKHDWLQJV\VWHPWREULQJERLOHUYROXPHWR&IRUDQKRXURQFHDGD\" Yes No
Electrical installation is accordance with BS7671 Yes
/RFDWLRQRIHOHFWULFDOLVRODWLRQVZLWFKWRVRODUFRQWUROSXPSXQLW
ALL INSTALLATIONS
The heating and hot water system complies with the appropriate Building Regulations Yes
The system and associated products have been installed and commissioned in accordance with the manufacturer’s instructions Yes
7KHHI¿FLHQWRSHUDWLRQRIV\VWHPDQGLWVFRQWUROVKDYHEHHQGHPRQVWUDWHGWRDQGXQGHUVWRRGE\WKHFXVWRPHU Yes
7KHPDQXIDFWXUHU¶VOLWHUDWXUHLQFOXGLQJ%HQFKPDUN&KHFNOLVWDQG6HUYLFH5HFRUGKDVEHHQH[SODLQHGDQGOHIWZLWKWKHFXVWRPHU Yes
Commissioning Engineer’s Signature
Customer’s Signature
7RFRQ¿UPVDWLVIDFWRU\GHPRQVWUDWLRQDQGUHFHLSWRIPDQXIDFWXUHU¶VOLWHUDWXUH
$OOLQVWDOODWLRQVLQ(QJODQGDQG:DOHVPXVWEHQRWL¿HGWR/RFDO$XWKRULW\%XLOGLQJ&RQWURO/$%&HLWKHUGLUHFWO\RUWKURXJKD
&RPSHWHQW3HUVRQV6FKHPH$%XLOGLQJ5HJXODWLRQV&RPSOLDQFH&HUWL¿FDWHZLOOWKHQEHLVVXHGWRWKHFXVWRPHU
© Heating and Hotwater Industry Council (HHIC)
www.centralheating.co.uk
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch AGS50-2 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info