620158
41
Zoom out
Zoom in
Vorherige Seite
1/125
Nächste Seite
40
Cleaning the motor protection filter
The motor protection filter should be cleaned regularly
by tapping out the dirt and rinsing.
Figure
Open the dust bag compartment lid.
Figure
Remove the motor protection filter from the appliance
in the direction of the arrow.
Disconnect the motor protection filter from the Bionic
f
ilter.*
Clean the motor protection filter by tapping out the
dirt.
If it is very dirty, the motor protection filter should be
rinsed. The filter must then be left to dry for at least
2
4 hours.
!
Please note: the Bionic filter must not come into
contact with water, as this will adversely affect the
c
orrect operation of the filter.
After cleaning, place the Bionic filter onto the motor
protection filter as necessary and push both filters
into the appliance.
Close the dust bag compartment lid.
Replacing the Bionic filter
If your appliance is equipped with a Bionic filter, it
should be replaced once it begins to lose its effect
(after approx. 1 year).
Figure
Open the dust bag compartment lid.
Figure
Remove the motor protection filter together with the
Bionic filter from the appliance.
Remove the old Bionic filter from the motor
protection filter and dispose of it.
Place the Bionic filter onto the motor protection filter.
Push the filters into the appliance and close the dust
bag compartment lid.
The motor protection filter must also be inserted into
the appliance if you no longer wish to use the Bionic
filter
Replacing the exhaust filter
Replacing the micro-hygiene filter
This should be replaced with every replacement filter pack.
Figure
Open the dust bag compartment lid.
Figure
Release the filter holder by turning the locking lever
in the direction of the arrow.
Remove the micro-hygiene filter. Insert the new
micro-hygiene filter into the appliance.
Insert the filter holder in the appliance and lock it in
place.
2
3*
2
1
24*
21
25
21
*
Dependent on model
Replacing the HEPA filter
If your vacuum cleaner is equipped with a HEPA filter,
this should be replaced once a year.
Figure
Open the dust bag compartment lid.
Figure
Unlock the Hepa filter by turning the locking lever in
the direction of the arrow and remove the filter from
the appliance.
Insert the new HEPA filter and lock it in place.
I
f you have vacuumed up fine dust particles, clean the
m
otor protection filter and, if necessary, replace the
micro-hygiene filter or HEPA filter.
Care
Always switch off the vacuum cleaner and disconnect
it from the mains before cleaning the vacuum cleaner.
The vacuum cleaner and plastic accessories can be
cleaned with a commercial plastic cleaner.
!
Do not use abrasive agents, glass or all-purpose
cleaning products. Never immerse the vacuum
cleaner in water.
If necessary, the dust compartment can be cleaned
with a second vacuum cleaner or simply wiped with
a dry cloth or dusting brush.
Subject to technical modifications.
2
6*
2
1
GA 9000 953 375_BSGL5_GL50 13.05.2014 15:08 Seite 40
41

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch BSGL5319 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info