809317
27
Zoom out
Zoom in
Vorherige Seite
1/44
Nächste Seite
Technical information
27
Compress 3400i AWS – 6721852066 (2023/01)
Table 10 Indoor unit with integrated electric booster heater
11.2 Primary circulation pump diagram (PC0)
Primary circulation pump diagram (PC0) for the heating system
CS3400iAWS 10 E.
Fig. 27 Capacity curve of the primary circulation pump (PC0)
11.3 System solutions
The outdoor unit and the indoor unit may only be installed according to
the manufacturer's official system solutions.
Deviating system solutions are impermissible. Warranty may be voided
in the case of damage and problems resulting from impermissible
installation.
The indoor unit is prepared to work without bypass/buffer, if the volume
and minimum flow declared in chapter 4.2 are permanently met and if
the pressure drop in the circuit is below the pressure available from the
primary circulation pump (PC0) as stated in table 10.
If the appliance is directly connected to the heating circuit (without
bypass or buffer tank) and consequently no heating circulation pump
(PC1) is installed, the primary circulation pump (PC0) must be set to
continuous operation mode. Use the control unit to select: Service menu
> Heat pump > Pumps > Prim. heating pump mode > On.
Some system configurations require accessories (buffer cylinder, 3-way
valve, mixing valve, DHW circulation pump). If a heating circulation pump
(PC1) is installed, this is controlled by the controller in the indoor unit.
The following table shows different system solutions:
Minimum flow (during defrosting)4) l/min 15
Minimum/maximum water operating temperature
(cooling5)/heating mode)
°C 7/80
Pump type Grundfos UPM2K 25-75 PWM (EEI≤0,23)6)
General Information
Installation altitude up to 2000m above sea level
IP rating IPX1
Dimensions (width x depth x height) mm 485 x 398 x 700
Weight kg 41
1) 400V 3N ~ AC 50 Hz. The outdoor unit must have a separate power supply.
2) For 230V ~1N AC 50 Hz. The outdoor unit must have a separate power supply.
3) Fuse characteristic gL/C.
4) If the minimum flow rate in the system cannot be ensured, a buffer cylinder is essential.
5) If cooling is available.
6) The benchmark for the most efficient circulators is EEI ≤ 0,20.
CS3400iAWS 10 E Unit CS3400iAWS 4
OR-S
CS3400iAWS 6
OR-S
CS3400iAWS 8
OR-S
CS3400iAWS 10
OR-S
0
1
2
3
4
5
6
7
8
0.0 0.5 1.0 1.5 2.0 2.5 3.0
H [m]
Q [m³/h]
0010039797-001
Heat distribution
system
Type of valves in
system
Outdoor unit Open system size (l) Electric booster
heater On/Off
System solution
UF heating/ Fan coils No auto control valves
or on/off valves with
open circuits
CS3400iAWS 4 OR-S <13 - Buffer1)
13<35 Electric booster heater
on
Direct system2) or
bypass
Electric booster heater
off
Buffer1)
>35 - Direct system2) or
bypass
On/off valves with no
open circuits
--Buffer
1)
No open circuits and
differential pressure
- - Serial buffer1)
27

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch Compress 3400i AWS wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Bosch Compress 3400i AWS

Bosch Compress 3400i AWS Bedienungsanleitung - Englisch - 2 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info