809324
4
Zoom out
Zoom in
Vorherige Seite
1/28
Nächste Seite
Product description
Compress 7000 AWM/AWMS 5-17 – 6721830635 (2021/02)
4
2 Product description
This is an original manual. This manual may not be translated without the
approval of the manufacturer.
The heat pump Compress 7000 AW is together with the indoor units
AWM, AWMS part of a series of heating systems that use outside air to
provide energy for water transferred heat and hot water. By reversing the
process and extract heat from the water and release it into the outdoor
air, the heat pump can if needed produce cooling. This however requires
the heating system to be set up for cooling.
The heating system is operated via a user interface, which is found in the
indoor unit. The user interface manages and supervises the system with
different settings for heat, cold, hot water and other operations. The
monitoring function will e.g. turn off the heat pump in case of
disturbances to avoid damage to vital components.
2.1 Typeplate
Compress 7000 AW: The typeplate is located on the backside of the
heat pump.
AWM / AWMS: The type plate is located on the top cover of the indoor
unit.
On the type plate there are information about output power, article
number, serial number and date of manufacturing.
2.2 Declaration of Conformity
The design and operating characteristics of this product comply with the
European and national requirements.
The CE marking declares that the product complies with all the
applicable EU legislation, which is stipulated by attaching this
marking.
The complete text of the Declaration of Conformity is available on the
Internet: worcester-bosch.co.uk.
2.3 Heat pump (outdoor unit)
The heat pump is inverter operated, which means that it will
automatically change the compressor speed to deliver the exact amount
of energy required at the moment. The fan is also RPM controlled and will
change its speed as needed. This provides the lowest possible energy
consumption.
The speed changes have an effect on the sound emissions, as higher
speed results in higher sound emission.
Defrosting
Ice might form on the evaporator during lower outside temperatures. In
case there is enough ice to inhibit the air flow through the evaporator, an
automatic defrosting will start. As soon as the ice is gone, the heat pump
returns to its normal operation.
If the outside temperature is above +5 °C the defrosting will be
performed alongside continued heat production, however if the
temperature is lower, the defrosting is done by ways of a 4-way valve
turning the heat medium direction in the circuit so that the hot gas from
the compressor melts away the ice. The duration of the defrost cycle
depends on the actual outdoor temperature and the amount of frost on
the evaporator.
2.3.1 Operating range of heat pump without auxiliary heater
The heat pump switches off at approx. 20 °C or +35 °C. The indoor
unit or an external heat source then take over the heating and DHW
heating. The heat pump restarts if the outdoor temperature exceeds
roughly – 17 °C or falls below +32 °C. In cooling mode the heat pump
switches off at roughly +45 °C and restarts at roughly +42 °C.
Fig. 1 Heat pump without auxiliary heater
[1] Maximum flow temperature (T0)
[2] Outdoor temperature (T1)
35
45
50
55
60
-30
T1[°C]
T0[°C]
30
25
20
15
10
-20 0-10 10 20 30 40
1
2
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch Compress 7000 AWM wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info