Operation
Compress 7000 AWM/AWMS 5-17 – 6721830635 (2021/02)
6
Vent the room correctly
Open the windows fully for a short period instead of leaving them ajar.
Leaving the windows ajar will let the heated air out of the room constantly
without increasing the air quality. Close the thermostatic valves or lower
the heating setting on the room controller while the room is vented.
3Operation
WARNING
Material damage from frost!
The heating or auxiliary heater may be irreparably damaged by frost.
Do not start the indoor unit if there is a possibility of the heating or
auxiliary heater being frozen.
3.1 Control unit
The user interface HPC 410 controls max. 4 heating circuits individually
in one of the respective control modes:
Outdoor-temp.-compensated
the flow temperature is adjusted based on the outside
temperature according to an optimised heating curve.
Outdoor-temp.-compensated with low end1)
the flow temperature is adjusted based on the outside
temperature according to a simplified heating curve.
For both of the control modes a room controller may be installed in the
reference room to allow the influence of the measured and required
room temperature. The heating curve is then adjusted accordingly.
The user interface HPC 410 is installed in the appliance and cannot be
used as room controller. Ask your contractor for available room controls.
Rule of thumb for outdoor-temp-compensated control with influence of
room temperature: the thermostatic valves in the reference room (the
room in which the remote control is installed) must be fully open!
The cooling function is not available in Belgium or Denmark.
The cooling menu items mentioned in this manual may be hidden if the
installed system is not suitable for cooling.
The electric booster or additional heater are not available for normal
operation in Denmark. The heater are however allowed to run in fault
mode, for extra DHW and thermal disinfection.
Depending on the software version of the user interface, the texts shown
in the display may differ from the texts in these instructions.
The adjustment ranges, default settings and functional scope may differ
from the information in these instructions, depending on the system
installed at the site.
If 2 or more heating circuits are installed, settings for different
heating circuits are available and are necessary.
If special system components and modules are installed (e.g.
MS 200 solar module, pool module MP 100), corresponding settings
are available and necessary.
If certain types of heat source are installed, additional settings may
be available and necessary.
3.1.1 Operation after power failure
At electric power failure or periods with disconnected heat source, no
settings are lost. The control unit will restart when the power is restored.
It is possible that time and date may need to be reset. No other settings
are needed.
3.1.2 Overview of control elements and symbols
Fig. 4 Control elements
[1] fav key: calls up the favourites menu
[2] extra DHW key: starts extra DHW charging
[3] DHW key: set the operating mode for DHW heating
[4] menu key: main menu (press briefly)
[5] info key: info menu or further information about the current
selection
[6] d key: returns to previous menu or discards a value (press
briefly); returns to the standard display (hold down)
[7] Selector: select (turn) and confirm (press)
If the display lighting is off, only the lighting goes on when the selector is
pressed for the first time. When the selector is turned and another
control element is pressed at the same time, the lighting is switched on
in addition to the effect described. The descriptions of the steps to be
carried out by the operator in these instructions always assume that the
lighting is activated. If no control element is actuated, the lighting turns
off automatically (after approx. 30 s with the standard display, after
approx. 30 min in the menu, after 24 h in the event of a fault).
Fig. 5 Symbols in the standard display (example display)
The standard display refers only to the displayed heating circuit.
Changing the required room temperature in the standard display only
affects the heating circuit displayed.
1) This setting is not available in Finlandor Sweden
0010032819-001
fav
menu
info
5
6
7
4
2
3
1
6 720 811 136-901.1O
6
1
3
7
2
4
5
5
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch Compress 7000 AWM wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info