Operation
17
Compress 7000 AWM/AWMS 5-17 – 6721830635 (2021/02)
3.4 Calling up information about the system
The current system values and the active operating conditions can be
displayed easily via the info menu. No changes can be made in this menu.
To open the info menu:
Press the info key in the standard display.
Menu: Sum./winter changeover
Table 21 Information about the heating
Menu: DHW
Table 22 Information about DHW
Menu: Ventilation
Table 23 Information about the ventilation unit
Menu: Pool
Table 24 Information about pool
Menu: Operating data
Table 25 Operation data
Menu: Energy consump.
Table 26 Total energy consumption data
Menu: Energy consump. > Electric auxiliary heater
Table 27 Energy consumption data for electric booster heater
Menu: Energy consump. > Compressor
Table 28 Energy consumption data for heat pump
Menu item Description
Heating/cooling
mode
Currently valid operating mode in the selected
heating circuit.
Set room temp. The desired room temperature that is currently valid
in the selected heating circuit:
In automatic mode, this can change several times
a day, if necessary.
In normal operation, it is always constant.
Measured room
temp.
Currently measured room temperature in the
selected heating circuit
Measured flow
temp.
Currently measured flow temperature in the
selected heating circuit
Menu item Description
Set temp. Desired DHW temperature.
Measured temp. Currently measured DHW temperature.
Menu item Description
Op. mode Currently selected operating mode and ventilation level
Outside temperature Display of Outside temperature
Supply air temp. Display of supply air temperature
Ex.air temp. Display of extract air temperature
Exhaust air temp. Display of exhaust air temperature
Reheat supp.air temp. Display of supply air temperature from the re-heater
Ex.air humid. Display of exhaust air humidity
Ex.air quality Display of exhaust air quality
Humidity remote ctrl Display of humidity in the installation room of the
remote control
Amb. air humid. Display of ambient air humidity
Amb. air quality Display of ambient air quality
Bypass Display of bypass-settings
Rem. filter elapsed
time
Display of duration in days until the next filter change
Menu item Description
Set pool
temperature
Desired pool temperature.
Current pool
temperature
Currently measured pool temperature.
Menu item Description
Control
operating hours
Hours run by the control since the heat pump was
commissioned or since the last reset.
Aux. heater
energy cons.
Output of the electric booster heater since
commissioning or since the last reset.
Op. hours for
comp. heat.
Hours run by the compressor in heating mode since
commissioning or since the last reset.
Op. hours for
comp. cool.
Hours run by the compressor in cooling mode since
commissioning or since the last reset.
Op. hours for
comp. DHW
Hours run by the compressor in DHW operation
since commissioning or since the last reset.
Op. hours for
comp. pool
Hours run by the compressor in pool operation since
commissioning or since the last reset.
Number of
heating starts
Number of compressor starts in heating mode since
commissioning or since the last reset.
Number of
cooling starts
Number of compressor starts in cooling mode since
commissioning or since the last reset.
Number of DHW
starts
Number of compressor starts in DHW operation
since commissioning or since the last reset.
Number of pool
starts
Number of compressor starts in pool operation since
commissioning or since the last reset.
Menu item Description
Total Cumulated total energy consumed by the heating
system.
Menu item Description
Total Cumulated total energy consumed by the electric
booster heater.
Heating Cumulated energy consumed by the electric booster
heater in heating mode.
DHW Cumulated energy consumed by the electric booster
heater in DHW mode.
Pool Cumulated energy consumed by the electric booster
heater in pool heating mode.
Menu item Description
Total Cumulated total energy consumed by the heat
pump.
Heating Cumulated energy consumed by the heat pump in
heating mode.
DHW Cumulated energy consumed by the heat pump in
DHW mode.
Cooling Cumulated energy consumed by the heat pump in
cooling mode.
Pool Cumulated energy consumed by the heat pump in
pool heating mode.
17

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch Compress 7000 AWM wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info