Operation
17
Compress 7001i/7400i AW AWE – 6721835320 (2021/09)
Table 19 General Settings
3.4 Calling up information about the system
The current system values and the active operating conditions can be
displayed easily via the info menu. No changes can be made in this menu.
To open the info menu:
Press the info key in the standard display.
Menu: Sum./winter changeover
Table 20 Information about the heating
Menu: DHW
Table 21 Information about DHW
Menu: Ventilation
Table 22 Information about the ventilation unit
Menu: Pool
Table 23 Information about pool
Menu: Operating data
Table 24 Operation data
Warning sound
blocked
If a buzzer has been installed a warning sound is
emitted as soon as an alarm occurs. The warning
sound can be suppressed at a settable time interval.
Reduced DHW
temp.
Setting for the reduced DHW mode. If [Yes] is set,
the DHW temperature is reduced if there are a
compressor fault. The function is used to reduce the
use of the auxiliary heater.
DHW temp.
correction
Correction of the DHW temperature displayed by
the user interface by up to ± 10 °C.
Time correction Time correction of the internal clock of the user
interface in s/week.
Standard display Settings for the display of additional temperatures in
the standard display.
Internet
password
Reset the personal password for the Internet
connection (only available if a communication
module is installed). The next time you log in, e.g.
using an App, you will automatically be prompted to
assign a new password.
Internet Make settings for the Internet connection (only
available if a communication module is installed).
[Establish connection]
[Pairing-Status]
[Activate hotspot]
[Activate WPS]
[Terminate connection]
[Connected network]
[Terminate connection]
Low-noise
operation
If activated the heat pump will run in reduced sound
operation during the set time period.
[Low-noise operation of]: set the start time for
the low noise operation.
[Low-noise operation until]: set the stop time for
the low noise operation.
[Min. outside temp.]: Below this outdoor
temperature the heat pump switches over to
normal operation.
Reset Reset all settings to the values set at commissioning.
Menu item Description
Heating/cooling
mode
Currently valid operating mode in the selected
heating circuit.
Set room temp. The desired room temperature that is currently valid
in the selected heating circuit:
In automatic mode, this can change several times
a day, if necessary.
In normal operation, it is always constant.
Measured room
temp.
Currently measured room temperature in the
selected heating circuit
Measured flow
temp.
Currently measured flow temperature in the
selected heating circuit
Menu item Description
Menu item Description
Set temp. Desired DHW temperature.
Measured temp. Currently measured DHW temperature.
Menu item Description
Op. mode Currently selected operating mode and ventilation level
Outside temperature Display of Outside temperature
Supply air temp. Display of supply air temperature
Ex.air temp. Display of extract air temperature
Exhaust air temp. Display of exhaust air temperature
Reheat supp.air temp. Display of supply air temperature from the re-heater
Ex.air humid. Display of exhaust air humidity
Ex.air quality Display of exhaust air quality
Humidity remote ctrl Display of humidity in the installation room of the
remote control
Amb. air humid. Display of ambient air humidity
Amb. air quality Display of ambient air quality
Bypass Display of bypass-settings
Rem. filter elapsed
time
Display of duration in days until the next filter change
Menu item Description
Set pool
temperature
Desired pool temperature.
Current pool
temperature
Currently measured pool temperature.
Menu item Description
Control
operating hours
Hours run by the control since the heat pump was
commissioned or since the last reset.
Aux. heater
energy cons.
Output of the electric booster heater since
commissioning or since the last reset.
Op. hours for
comp. heat.
Hours run by the compressor in heating mode since
commissioning or since the last reset.
Op. hours for
comp. cool.
Hours run by the compressor in cooling mode since
commissioning or since the last reset.
Op. hours for
comp. DHW
Hours run by the compressor in DHW operation
since commissioning or since the last reset.
Op. hours for
comp. pool
Hours run by the compressor in pool operation since
commissioning or since the last reset.
Number of
heating starts
Number of compressor starts in heating mode since
commissioning or since the last reset.
Number of
cooling starts
Number of compressor starts in cooling mode since
commissioning or since the last reset.
Number of DHW
starts
Number of compressor starts in DHW operation
since commissioning or since the last reset.
Number of pool
starts
Number of compressor starts in pool operation since
commissioning or since the last reset.
17

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

bosch-compress-7001i-aw

Suche zurücksetzen

  • Wenn ich die Wassertemperatur auf 40 Grad senke, heizt sie sich dann einmal im Monat automatisch auf 60 Grad auf, um Legionellen abzutöten? Eingereicht am 13-9-2022 14:58

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch Compress 7001i AW wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Bosch Compress 7001i AW

Bosch Compress 7001i AW Bedienungsanleitung - Deutsch - 28 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info