6720856749 (2016/03)CR50
Old electrical and electronic appliances | 9
Table 10
Table 11
Table 12
Table 13
Table 14
Table 15
Table 16
Table 17
Table 18
8 Old electrical and electronic appliances
Electrical or electronic devices that are no longer
serviceable must be collected separately and sent
for environmentally compatible recycling (in
accordance with the European Waste Electrical
and Electronic Equipment Directive).
To dispose of old electrical or electronic devices, you should
use the return and collection systems put in place in the country
concerned.
Check the hot water
temperature sensor
according to table
If values do not match,
replace the sensor
Check the voltage at the
connecting terminals of the
hot water temperature sensor
in the controller according to
table
If the sensor values matched,
but the voltage values do not
match, replace the controller
A01 - 810 - [hot water remains cold]
Test procedure/cause Corrective measure
If the DHW priority was
deselected and heating and
DHW are running in parallel,
the boiler's performance may
not be not sufficient
Set water heating to "priority"
Check the hot water
temperature sensor
according to table
Replace the sensor if there are
deviations from the table
values
A11 - 1000 - [System configuration not confirmed]
Test procedure/cause Corrective measure
System configuration not
completed
Configure system completely
and confirm
A11 - 1010 - [No communication via BUS interface EMS 2]
Test procedure/cause Corrective measure
Check whether BUS cable
was connected incorrectly
Rectify wiring faults and
switch controller off and on
again
Check whether BUS cable is
defective. Turn the controller
off and on again.
Repair or replace the bus
cable
Replace defective user
interface
A11 - 1038 - [Invalid time/date]
Test procedure/cause Corrective measure
Date/time not yet set Set date/time
Prolonged loss of power supply Set date/time
A01 - 808 - [DHW heating: hot water temperature sensor
1 faulty - replacement mode active]
Test procedure/cause Corrective measure
A31 - 3021 - [Heating circuit flow temperature sensor
faulty - standby mode active]
Test procedure/cause Corrective measure
Check configuration. The
selected setting requires a
flow temperature sensor
Change configuration
Check flow temperature
sensor according to table
If values do not match,
replace the sensor
A61 - 1010 - [No communication via BUS interface EMS 2]
Test procedure/cause Corrective measure
Check whether BUS cable was
connected incorrectly
Rectify wiring faults and
switch controller off and on
again
Check whether BUS cable is
defective. Turn the controller
off and on again.
Repair or replace the bus
cable
Replace defective user
interface
A61 - 3091 - [Room temperature sensor faulty]
Test procedure/cause Corrective measure
User interface faulty Restart auto-
configuration. All users
must be on the BUS.
Replace user interface
Hxx - ... - [...]
Test procedure/cause Corrective measure
For instance, service interval
of heat source elapsed.
Service required; see
documents for the heat
source.
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch CR 50 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Bosch CR 50

Bosch CR 50 Bedienungsanleitung - Englisch - 12 seiten

Bosch CR 50 Bedienungsanleitung - Holländisch - 12 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info