21
Prior to installation
❑ Flat ducts must have an internal cross-
section that equates to that of round
pipes.
There should be no sharp bends.
For optimum extractor hood efficiency:
❑ Short, smooth air exhaust pipe.
❑ As few bends in the pipe as possible.
❑ Diameter of pipe to be as large as
possible and no tight bends in pipe.
If long, rough exhaust-air pipes,
many pipe bends or smaller pipe
diameters are used, the air extraction
rate will no longer be at an optimum
level and there will be an increase in
noise.
ṇThe manufacturer of the extractor
hoods accepts no liability for complaints
which can be attributed to the design
and layout of the pipework.
❑ If pipes have different diameters:
Insert sealing strip.
❑ For exhaust-air mode, ensure that
there is an adequate supply of fresh air.
Round pipes
Internal diameter
Flat ducts
Cross-section
l
120 mm
113 cm
2
Air connector l 120 mm
Mount the pipe
directly onto the air
outlet on the hood.