1 609 92A 0KB | (25.4.14) Bosch Power Tools
Accuracy Check of the Distance Measurement
The accuracy of the distance measurement can be checked as
follows:
Select a permanently unchangeable measuring section
with a length of approx. 1 to 10 metres; its length must be
precisely known (e.g. the width of a room or a door open-
ing). The measuring distance must be indoors; the target
surface for the measurement must be smooth and reflect
well.
–Measure the distance 10 times after another.
The deviation of the individual measurements from the mean
value must not exceed ±2 mm (max.). Log the measure-
ments, so that you can compare their accuracy at a later point
of time.
Working with the Tripod (Accessory)
The use of a tripod is particularly necessary for larger distanc-
es. Position the measuring tool with the 1/4" thread 19 onto
the quick-change plate of the tripod 26 or a commercially
available camera tripod. Tighten the measuring tool with the
locking screw of the quick-change plate.
Set the corresponding reference level for measurement with
a tripod by pushing button 10 (the reference level is the
thread).
Working with the Measuring Rail (see figures IK)
The measuring rail 24 can be used for a more accurate grade
measurement result. Distance measurements are not possi-
ble with the measuring rail.
Place the measuring tool into the measur-
ing rail 24 as shown and lock the measur-
ing tool with locking lever 25. Press the
measuring button 2 to activate the “Meas-
uring rail” operating mode.
Regularly check the accuracy of the grade
measurement by carrying out a reversal measurement or with
the spirit levels of the measuring rail.
In case of greater deviation, the measuring tool must be recal-
ibrated. For this, press and hold the grade measurement but-
ton 3. Follow the directions on the display.
To end the “Measuring rail” operating mode, switch the meas-
uring tool off and remove it from the measuring rail.
Troubleshooting – Causes and Corrective
Measures
Cause Corrective Measure
Temperature warning indicator (k) flashing; measure-
ment not possible
The measuring tool is outside the
operating temperature range from
– 10 ° C to + 50 °C (in the function
continuous measurement up to
+40 °C).
Wait until the measuring
tool has reached the op-
erating temperature
“ERROR” indication in the display
Addition/Subtraction of measured
values with different units of
measure
Only add/subtract
measured values with
the same units of
measure
The angle between the laser beam
and the target is too acute.
Enlarge the angle be-
tween the laser beam
and the target
The target surface reflects too
intensely (e.g. a mirror) or insuffi-
ciently (e.g. black fabric), or the
ambient light is too bright.
Work with the laser tar-
get plate 28 (accessory)
The laser beam outlet 16 or the
reception lens 17 are misted up
(e.g. due to a rapid temperature
change).
Wipe the laser beam out-
let 16 and/or the recep-
tion lens 17 dry using a
soft cloth
Calculated value is greater than
999999 m/m
2
/m
3
.
Divide calculation into
intermediate steps
Indication “>60°” or “<–60°” on the display
The inclination measuring range
for the measuring mode and/or
the reference plane has been
exceeded.
Carry out the measure-
ment within the speci-
fied angle range.
“CAL” and “ERROR” indication in the display
The calibration of the grade meas-
urement was not carried out in the
correct sequence or in the correct
positions.
Repeat the calibration
according to the instruc-
tions on the display and
in the operating instruc-
tions.
The surfaces used for the calibra-
tion were not accurately aligned
(horizontal or vertical).
Repeat the calibration
on a horizontal or verti-
cal surface; if required,
check the surface first
with a level.
The measuring tool was moved or
tilted while pressing the button.
Repeat the calibration
and hold the measuring
tool in place while press-
ing the button.
Battery charge-control indicator (g), temperature
warning (k) and “ERROR” indication in the display
Temperature of the measuring tool
not within the allowable charge-
temperature range
Wait until the charge-
temperature range is
reached.
OBJ_BUCH-1347-006.book Page 26 Friday, April 25, 2014 3:28 PM
26

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch GLM 80 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info