Bosch Power Tools 1 609 92A 01C | (15.11.13)
7 Camera head
8 Camera lens
9 Illumination light in camera head
10 Battery pack*
11 Battery unlocking button
12 Camera cable, extension*
13 Socket sleeve of camera connection
14 Camera connection
15 Magnet
16 Hook
17 Mirror
18 Video output socket
19 Video cable
*Accessories shown or described are not part of the standard
delivery scope of the product. A complete overview of accessories
can be found in our accessories program.
Technical Data
Assembly
Before any work on the inspection camera itself (e.g.
assembling, maintenance, etc.) as well as when trans-
porting and storing, remove the battery from the in-
spection camera.
Battery Charging
Use only the battery chargers listed on the graphics
page. Only these battery chargers are matched to the lith-
ium-ion battery used in your inspection camera.
Note: The battery is supplied partially charged. To ensure full
capacity of the battery, completely charge the battery in the
battery charger before using your power tool for the first time.
The lithium-ion battery can be charged at any time without re-
ducing its service life. Interrupting the charging procedure
does not damage the battery.
The battery is equipped with a NTC temperature control
which allows charging only within a temperature range of be-
tween 0 °C and 45 °C. A long battery service life is achieved
in this manner.
Battery Charge-control Indication
When the inspection camera is switched on, the charge con-
dition of the battery is indicated on the display 5:
Removing the battery
To remove the battery 10, press the battery unlocking but-
tons 11 and pull the battery toward the rear out of the inspec-
tion camera. Do not exert any force when doing this.
Mounting the Camera Cable (see figure A)
For operation of the inspection camera, the camera cable 6
must be mounted to the hand unit 1.
Insert the camera cable 6 into the camera connection 14 in
such a manner that the pin of the camera cable engages into
the opening of the camera connection as shown in the figure.
Slide the socket sleeve 13 on the camera connection over the
camera cable and hand-tighten in clockwise direction.
To remove the camera cable 6, unscrew socket sleeve 13 in
anticlockwise direction and pull the camera cable off.
Mounting the Camera Cable Extension (Accessory)
To mount a camera cable extension 12, the mounted camera
cable 6 must be removed.
Then, mount the extension 12 onto camera connection 14 as
described under “Mounting the Camera Cable” and tighten.
If required, further extensions can be mounted in the same
manner. However, the image quality decreases when exceed-
ing a total length approx. 10 m (incl. camera cable).
Screw the camera cable 6 onto the last extension 12 as de-
scribed under “Mounting the Camera Cable”.
Check if the camera cable and the extension are firmly
connected. The camera cable and the extension are only
water-tight when firmly connected. Untight connections
increase the risk of an electric shock or damage to the in-
spection camera.
Mounting the Mirror, Magnet or Hook
(see figure B)
The mirror 17, the magnet 15 and the hook 16 can be mount-
ed to the camera head 7 as auxiliary aids.
Slide one of the three auxiliary aids to the stop onto the recess
on the camera head 7 as shown in the figure.
Digital Inspection Camera GOS 10,8 V-LI
Article number
3 601 B41 0..
Rated voltage
V= 10.8
Operating temperature
°C –20...+65
Storage temperature
(hand unit without battery)
°C –30...+80
Relative humidity
%595
1)
Smallest bending radius of
camera cable
mm 120
Diameter of camera head
mm 17/9.5
Depth-of-field range of
camera lens
mm 38 –
Display size
mm 68.6
Display resolution
320 x 240
Format of video output
NTSC
Operating life time, approx.
h/Ah 11.5
Weight according to
EPTA-Procedure 01/2003
kg 0.68
Dimensions
(lengthx widthx height)
mm 166 x 66 x 45
1) Free of moisture condensation
Indication Capacity
>1/2
<1/2
Reserve
OBJ_BUCH-1512-004.book Page 7 Friday, November 15, 2013 11:06 AM
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch GOS 10.8 V-LI wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info