544290
10
Zoom out
Zoom in
Vorherige Seite
1/178
Nächste Seite
10 | English
1 609 92A 0KW | (16.5.14) Bosch Power Tools
Technical Data
Assembly
Inserting/Replacing the Batteries
Alkali-manganese batteries are recommended for the meas-
uring tool.
To open the battery compartment 3, turn the latch 2 in clock-
wise direction to position and pull off the battery lid.
Insert the batteries provided. When inserting, pay attention
to the correct polarity according to the representation on the
inside of the battery compartment.
Position the battery lid to the bottom of the housing and then
push it upward. To lock the battery lid, turn the latch 2 in anti-
clockwise direction to the position.
When the laser beams flash slowly during operation, the bat-
teries are low. When the flashing begins, the measuring tool
can be operated for approx. 8 h.
Always replace all batteries at the same time. Only use batter-
ies from one brand and with the identical capacity.
Remove the batteries from the measuring tool when
not using it for extended periods. When storing for
extended periods, the batteries can corrode and self-dis-
charge.
Operation
Initial Operation
Protect the measuring tool against moisture and direct
sun light.
Do not subject the measuring tool to extreme tempera-
tures or variations in temperature. As an example, do
not leave it in vehicles for a long time. In case of large vari-
ations in temperature, allow the measuring tool to adjust to
the ambient temperature before putting it into operation.
In case of extreme temperatures or variations in tempera-
ture, the accuracy of the measuring tool can be impaired.
Avoid heavy impact to or falling down of the measuring
tool. Damage to the measuring tool can impair its accura-
cy. After heavy impact or shock, compare the laser lines or
plumb beams with a known horizontal or vertical reference
line or with already checked plumb points.
Switch the measuring tool off during transport. When
switching off, the levelling unit, which can be damaged in
case of intense movement, is locked.
Switching On and Off
To switch on the measuring tool, push the On/Off switch 4
upward so that “I” is indicated on the switch. Immediately af-
ter switching on, the measuring tool sends a laser beam out of
each exit opening 1.
Do not point the laser beam at persons or animals and
do not look into the laser beam yourself, not even from
a large distance.
Do not leave the switched-on measuring tool unattend-
ed and switch the measuring tool off after use. Other
persons could be blinded by the laser beam.
To switch off the measuring tool, push the On/Off switch 4
downward so that “0” is indicated on the switch. When
switching off, the levelling unit is locked.
Setting the Automatic Switch-off
By default, the measuring tool automatically shuts off
20 minutes after being switched on.
The automatic switch-off can be set from 20 minutes to
8 hours. For this, switch the measuring tool on, then immedi-
ately off, and then on again within 4 s. To confirm the change,
all laser beams will flash quickly for 2 s after switching on the
second time.
Do not leave the switched-on measuring tool unattend-
ed and switch the measuring tool off after use. Other
persons could be blinded by the laser beam.
When switching on the measuring tool the next time, the auto-
matic switch-off is set to 20 minutes again.
Working with Automatic Levelling
Position the measuring tool on a level and firm support, attach
it to the holder 8 or to the tripod 18.
After switching on, the automatic levelling function automati-
cally compensates irregularities within the self-levelling range
of ±5° (longitudinal axis) and ±3° (lateral axis). The levelling
is finished as soon as the laser points do not move any more.
Point Laser GPL 3
Article number
3 601 K66 1..
Working range
30 m
Levelling Accuracy
±0.3mm/m
Self-levelling range (typical)
alongside the
longitudinal axis
lateral axis
±5°
±3°
Levelling duration, typically <4s
Operating temperature
–10 °C...+40 °C
Storage temperature
–20 °C...+70 °C
Relative air humidity, max.
90 %
Laser class
2
Laser type
635 nm, <1 mW
Tripod mount
1/4"
Batteries
3 x 1.5 V LR06 (AA)
Operating time, approx.
24 h
Weight according to
EPTA-Procedure 01/2003
0.25 kg
Dimensions (length x width x
height)
104 x 40 x 80 mm
Degree of protection
IP 5X
The measuring tool can be clearly identified with the serial number 7 on
the type plate.
OBJ_BUCH-807-004.book Page 10 Friday, May 16, 2014 7:51 AM
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch GPL 3 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info