FACTORY SETTINGS
6 720 806 630 (2013/02)16
14 FACTORY SETTINGS
14.1 FACTORY SETTINGS
The tables show the values which have been preset at the factory (F
value). These values can be modified by the user =[0] via user levels
Menu and Advanced.
The installer can access the items in the installation and service menu
=[1] listed in the following table after changing the access level under
Menu or Advanced menu. Only the items which are identified with a [0]
are accessible to the user.
Cooling function is not available in this product, so any
reference to this in the menus can be disregarded.
Menu Level F value
Fast restart of heat pump 1No
Start up
_”_\Setting the clock
_”_\_”_\Set date 1yy-mm-dd
_”_\_”_\Set time 1 hh:mm:ss
_”_\T1 maximum set point value 145 °C
_”_\External input
_”_\_”_\Activated if 1 Closed
_”_\_”_\Change in temperature 1 0 °C
_”_\_”_\Stop hot water loading 1No
_”_\_”_\Stop heating production 1 No
_”_\_”_\Additional heat only 1 No
_”_\_”_\Limit electrical capacity to 1 3/3
_”_\_”_\External blocking 1No
_”_\_”_\Safety thermostat 1 No
_”_\_”_\Stop additional heat hot water 1No
_”_\_”_\Stop additional heat radiators 1 No
_”_\Lowest outdoor temperature 1-10 °C
_”_\Accessory board function 1 No
_”_\Max limit E12.T1 Set point value 145 °C
_”_\Connected extra sensors
_”_\_”_\ T3 acknowledged 1Yes
_”_\_”_\T5 acknowledged (T5) 1 Yes
_”_\Manual operation 1No
_”_\Operating mode, additional heater
_”_\_”_\Additional heat only 1 No
_”_\_”_\Block additional heat 1 No
_”_\Correct sensor 1 0
_”_\Anti-jamming mode time 1 02:00
_”_\Alarm buzzer interval 11 min
_”_\Display
_”_\_”_\Contrast 0 27
_”_\_”_\Brightness 0 100
_”_\System pressure sensor connected 1Yes
_”_\Operation alternative G2 1 Continuous
Room temperature setting (T5) 020°C
Room temperature setting, heating system 2 020°C
Extra hot water 0 0 h
Table 4 Menu
Advanced menu Level F value
Heating/cooling
_”_\Minimum outdoor temperature of heat
curve
1–10 °C
_”_Heating system temperature
_”_\_”_\Heat curve 0V=20.0 °C
H=35.0 °C
_”_\_”_\Hysteresis
_”_\_”_\_”_\Quick acceleration 15.0 °C
_”_\_”_\_”_\Quick brake 1 1.0 °C
_”_\_”_\_”_\Quick stop 110.0 °C
_”_\_”_\_”_\Integration time 1 60°min
_”_\_”_\_”_\Rad brake temp increase 11.0 °C
_”_\_”_\_”_\Rad brake time 1 0 min
_”_\Room sensor setting
_”_\_”_\Room temperature setting 0 20 °C
_”_\_”_\Room sensor interval 0 3K
_”_\_”_\Room sensor influence
_”_\_”_\_”_\Change factor 02.0
_”_\_”_\Blocking time 0 4 hrs
_”_\Time limited settings
_”_\_”_\Time control heating
_”_\_”_\_”_\Day and time 0Off
_”_\_”_\_”_\Change in temperature 0 –10 °C
_”_\_”_\Holiday
_”_\_”_\_”_\Date 0 Off
_”_\_”_\_”_\Change in temperature 0-10 °C
_”_\_”_\External input
_”_\_”_\_”_\Activated if 1Closed
_”_\_”_\_”_\Change in temperature 0 0 °C
_”_\Heating season
_”_\_”_\Heating season limit 0 18 °C
_”_\_”_\Delay 04hrs
_”_\_”_\Direct start limit 0 10 °C
_”_\Heating, maximum operating time at hot
water demand
020 min
_”_\Shut down protection, change over hot
water to heating
1 300 s
_”_\Maximum speed compressor 1 7
_”_\Quick acceleration time 1 15 min
_”_\Quick brake time 15min
Table 5 Advanced menu
Advanced menu Level F value
_”_\Temperature heating system 2
_”_\_”_\Heat curve 0V=20.0 °C
H=35.0 °C
_”_\_”_\Room sensor settings
_”_\_”_\_”_\Room temperature setting 020 °C
_”_\_”_\_”_\Room sensor influence
_”_\_”_\_”_\_”_\Change factor 05,0
_”_\_”_\_”_\_”_\Blocking time 0 4 hrs
_”_\_”_\Time limited settings
_”_\_”_\_”_\Time control heating
_”_\_”_\_”_\_”_\Day and time 0Off
_”_\_”_\_”_\_”_\Change in temperature 0 -10 °C
Table 6 Advanced menu
16

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch Greensource Hydrolight - Hydrocomfort wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info