594588
15
Zoom out
Zoom in
Vorherige Seite
1/198
Nächste Seite
English | 15
Bosch Power Tools 1 609 92A 110 | (16.12.14)
Declaration of Conformity
We declare under our sole responsibility that the product de-
scribed under “Technical Data” is in conformity with all rele-
vant provisions of the directives 2011/65/EU, 2014/30/EU,
2006/42/EC including their amendments and complies with
the following standards: EN 60745-1, EN 60745-2-11.
Technical file (2006/42/EC) at:
Robert Bosch GmbH, PT/ETM9,
70764 Leinfelden-Echterdingen, GERMANY
Robert Bosch GmbH, Power Tools Division
70764 Leinfelden-Echterdingen, GERMANY
Leinfelden, 13.11.2014
Assembly
Battery Charging
Use only the chargers listed in the technical data. Only
these chargers are matched to the lithium-ion battery of
your power tool.
Note: The battery supplied is partially charged. To ensure full
capacity of the battery, completely charge the battery in the
battery charger before using your power tool for the first time.
The lithium-ion battery can be charged at any time without re-
ducing its service life. Interrupting the charging procedure
does not damage the battery.
The lithium-ion battery is protected against deep discharging
by the “Electronic Cell Protection (ECP)”. When the battery is
empty, the machine is switched off by means of a protective
circuit: The inserted tool no longer rotates.
Do not continue to press the On/Off switch after the
machine has been automatically switched off. The bat-
tery can be damaged.
Observe the notes for disposal.
Removing the battery
The battery 9 is equipped with two locking levels that should
prevent the battery from falling out when pushing the battery
unlocking button 8 unintentionally. As long as the battery is
inserted in the power tool, it is held in position by means of a
spring.
To remove the battery 9, press the battery unlocking button 8
and pull the battery out of the power tool toward the rear. Do
not exert any force.
Battery Charge-control Indication (see figure A)
The three green LEDs of the battery charge-control indicator
12 indicate the charge condition of the battery 9. For safety
reasons, it is only possible to check the status of the charge
condition when the machine is at a standstill.
Press button 11 to indicate the charge condition. This is also
possible when the battery 9 is removed.
When no LED lights up after pushing button 11, then the bat-
tery is defective and must be replaced.
Replacing/Inserting the Saw Blade
Before any work on the power tool, remove the battery.
When mounting the saw blade, wear protective gloves.
Danger of injury when touching the saw blade.
When changing the saw blade, take care that the saw
blade holder is free of material residue, e. g. wood or
metal shavings.
Selecting a Saw Blade
Use only saw blades suitable for the material being worked.
An overview of recommended saw blades can be found at the
beginning of these instructions. Use only ½" universal shank
saw blades. The saw blade should not be longer than required
for the intended cut.
Use a thin saw blade for narrow curve cuts.
Inserting the Saw Blade (see figure B)
Press the saw blade 1 firmly into the saw blade holder 3 until
it can clearly be heard to engage. This causes the locking
sleeve 4 to turn by approx. 90° and locks the saw blade.
If the saw blade 1 is not locked, turn the locking sleeve 4 ap-
prox. 90° in the direction of the arrow until it locks in the open
position and a “click” can be heard. Then press the saw blade
1 into the saw blade holder 3 again.
Check the tight seating of the saw blade. A loose saw
blade can fall out and lead to injuries.
For certain work, the saw blade 1 can also be turned through
180° (with the teeth pointed upwards) and re-inserted again.
Ejecting the Saw Blade (see figure C)
When ejecting the saw blade, hold the machine in such
a manner that no persons or animals can be injured by
the ejected saw blade.
Turn the locking sleeve 4 approx. 90° in the direction of the
arrow. The saw blade 1 is ejected.
Dust/Chip Extraction
Dusts from materials such as lead-containing coatings,
some wood types, minerals and metal can be harmful to
one’s health. Touching or breathing-in the dusts can cause
allergic reactions and/or lead to respiratory infections of
the user or bystanders.
Certain dusts, such as oak or beech dust, are considered
as carcinogenic, especially in connection with wood-treat-
ment additives (chromate, wood preservative). Materials
containing asbestos may only be worked by specialists.
Provide for good ventilation of the working place.
It is recommended to wear a P2 filter-class respirator.
Henk Becker
Executive Vice President
Engineering
Helmut Heinzelmann
Head of Product Certification
PT/ETM9
LED Capacity
Continuous lighting 3 x green 2/3
Continuous lighting 2 x green 1/3
Continuous lighting 1 x green <1/3
Flashing light 1 x green Reserve
OBJ_BUCH-760-006.book Page 15 Tuesday, December 16, 2014 4:21 PM
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch GSA 18 V-LI Professional wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info