Mark the centre of the 45° laser line at a distance of
5m as point VII as near as possible next to the point I.
–The difference d of the two points VII and I is the actu-
al deviation of the 0° laser line and the 45° laser line.
The measuring length 4 x 5 m = 20 m has a maximum
admissible deviation of: 20 m x ±
0.4 mm/m* = ±8 mm.
Therefore, the maximum difference d between the points
I and VII may be 8 mm or less.
* The value ±0,4 mm/m results from the angle accuracy
±
0.2 mm/m plus a possible uncertainty of 0.2 mm/m
while turning.
Working Advice
Always position the measuring tool flat on the floor
or fix it flat on the wall. In case of uneven positioning
or fixing, the angle is smaller than 45° and 90°.
Always use the centre of the laser line for marking.
The width of the laser line changes with the distance.
Never use the laser lines that the measuring tool
standing on the floor projects on the wall for align-
ment. The measuring tool is not self-levelling. There-
fore, the line on the wall is distorted.
The reference point for the alignment of tiles is the
crossing point P of the laser lines directly in front of
the measuring tool. In order to mark an angle, the
measuring tool has to be turned at this crossing
point, see figure F.
Position the measuring tool only on a clean levelling
plate 10. The measuring tool cannot stand level on an
uneven, soiled levelling plate surface, which could lead
to faulty measuring results.
Working with the levelling plate (see figures DE)
Using the levelling plate 10 you can position the measur-
ing tool flat on an uneven or unstable floor.
The levelling plate 10 can also be used as a wall bracket
for the measuring tool. Fix the levelling plate (securing it
against slipping) on a wall or an inclined surface using e. g.
standard screws. Use a level to fix the levelling plate flat
on the surface.
Positioning of the measuring tool on the levelling
plate: Position the measuring tool with the magnets 4 on
the underside on the levelling plate 10. The line grid on
the upper side of the levelling plate facilitates the precise
positioning of the measuring tool. In order to mark 90° or
45° angles, position the levelling plate at a reference edge
or a projection on a wall and position the measuring tool
as illustrated on the upper side of the levelling plate.
Working with the laser target plate/ceiling measure-
ment plate (see figure A)
The laser target plate 9 or the ceiling measurement plate
14 improves the visibility of the laser beam under unfa-
vourable conditions and at longer distances.
The reflective part of the laser target plate 9 improves the
visibility of the laser line. Thanks to the transparent part,
the laser line is also visible from the back side of the laser
target plate.
The ceiling measurement plate 14 (accessory) can also
be used for marking the laser lines. Like the laser target
plate, it has a reflective and a transparent part.
Laser Viewing Glasses (Accessory)
The laser viewing glasses filter out the ambient light. This
makes the red light of the laser appear brighter for the
eyes.
Do not use the laser viewing glasses as safety gog-
gles. The laser viewing glasses are used for improved
visualisation of the laser beam, but they do not protect
against laser radiation.
Do not use the laser viewing glasses as sun glasses
or in traffic. The laser viewing glasses do not afford
complete UV protection and reduce colour perception.
Work Examples
Checking right angles (see figure A)
Position the measuring tool in one corner of the room and
position it so that the 0° laser line runs parallel to the ref-
erence line (e.g. wall). Measure the distance between the
laser line and the reference line directly at the measuring
tool and at the longest possible distance from the measur-
ing tool. Align the measuring tool so that both distances
are identical.
Then measure at at least two different points the distanc-
es between the 90° laser line and the wall. If the distances
to the 90° laser line are identical, the walls are at the right
angle.
OBJ_BUCH-828-004.book Page 20 Friday, May 16, 2014 1:02 PM
20

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch GTL 3 Professional wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info