786202
31
Zoom out
Zoom in
Vorherige Seite
1/499
Nächste Seite
English | 31
Protective guard for grinding
Place the protective guard
(15) onto the holder on the
power tool until the coding
cams of the protective guard
are aligned with the holder.
When doing so, press and
hold the unlocking lever (1).
Press the protective guard
(15) onto the spindle collar
until the shoulder of the pro-
tective guard is sitting on the
flange of the power tool and
rotate the protective guard
until it audibly clicks into
place.
Adjust the position of the protective guard (15) to meet the
requirements of the operation. To do this, push the unlock-
ing lever (1) upward and rotate the protective guard (15)
into the required position.
uAlways position the protective guard(15) such that
the two cams on the unlocking lever(1) engage in the
corresponding openings on the protective guard(15).
uAdjust the protective guard (15) such that sparking in
the direction of the operator is prevented.
uThe protective guard (15) must only be adjustable
while the unlocking lever (1) is actuated. Otherwise,
the power tool must not be used any more under any
circumstances and must be sent to the after-sales ser-
vice.
Note: The coding cams on the protective guard (15) ensure
that only a protective guard that is suitable for the power
tool can be fitted.
Protective guard for cutting
uFor cutting, always use the protective guard for
cutting(17) or the protective guard for grinding (15)
together with the cover for cutting(18).
uProvide sufficient dust extraction when cutting stone.
The protective guard for cutting(17) is fitted in the same
way as the protective guard for grinding(15).
Metal cover for cutting
Fit the metal cover for cutting(18) on the protective guard
for grinding(15) (see figureA): Swivel the tool retainer back
(). Attach the cover(18) to the protective guard for
grinding(15) (). Press the tool retainer firmly into place
on the protective guard(15) ().
To remove the cover (see figureB), press the button on the
tool retainer () and swivel it back (). Remove the
cover(18) from the protective guard(15) ().
Plastic cover for cutting
Attach the plastic cover for cutting(18) to the protective
guard for grinding(15) (see figureC). The cover(18) aud-
ibly and visually engages on the protective guard(15).
To remove the cover (see figureD), unlock the cover(18) on
the left- or right-hand side of the protective guard(15) ()
and remove the cover ().
Extraction guard for cutting with a guide block
The extraction guard for cutting with a guide block (29) is fit-
ted in the same way as the protective guard for grinding
(15).
Hand guard
uAlways fit the hand guard (22) when working with the
rubber sanding pad (23) or with the cup brush/conical
brush/diamond annular cutter.
Attach the hand guard (22) to the side handle (11).
Standard auxiliary handle/low-vibration auxiliary handle
Screw the auxiliary handle (11)/(12) on the right or left of
the machine head depending on the working method.
uDo not operate your power tool without the auxiliary
handle(11)/(12).
uDo not continue to use the power tool if the auxiliary
handle (11)/(12) is damaged. Do not make any altera-
tions to the auxiliary handle (11)/(12).
The low-vibration auxiliary
handle (12) reduces vibra-
tion, enabling the tool to be
used safely and more com-
fortably.
Fitting and removing abrasive tools
Follow the special assembly instructions for
X-LOCK application tools.
uRemove the battery from the power tool before carry-
ing out work on the power tool (e.g. maintenance,
changing tool, etc.). The battery should also be re-
moved for transport and storage. There is risk of injury
from unintentionally pressing the on/off switch.
uDo not touch grinding and cutting discs until they have
cooled down. The discs can become very hot while work-
ing.
uOnly use original X-LOCK application tools that carry the
X-LOCK logo. A maintained clamping gauge of max.
1.6mm can only be guaranteed with original X-LOCK ap-
plication tools. A higher clamping gauge can lead to insec-
ure clamping, potentially causing the clamp tool to come
loose.
uX-LOCK application tools do not need additional clamping
flanges or support flanges.
uMake sure that the application tool and the holder are not
deformed and are free from dirt and particles.
Pay attention to the dimensions of the abrasive tools.
Make sure that both X-LOCK catches are open (see figure
below) before fitting the X-LOCK application tool.
If necessary, clean the area between the two X-LOCK
catches.
Fitting the abrasive tool
Place the grinding/cutting/flap disc in a central position
on the X-LOCK holder, parallel to the bearing surface
and with the right side facing up.
Push the disc into the holder.
Bosch Power Tools 1 609 92A 6WT | (24.06.2022)
31

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch GWX 18V-15 P wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info