786298
19
Zoom out
Zoom in
Vorherige Seite
1/291
Nächste Seite
English | 19
The vibration level given in these instructions has been
measured in accordance with a standardised measuring pro-
cedure and may be used to compare power tools. It can also
be used for a preliminary estimation of exposure to vibra-
tion.
The stated vibration level applies to the main applications of
the power tool. However, if the power tool is used for differ-
ent applications, with different application tools or poorly
maintained, the vibration level may differ. This can signific-
antly increase the exposure to vibration over the total work-
ing period.
To estimate the exposure to vibration accurately, the times
when the tool is switched off or when it is running but not ac-
tually being used should also be taken into account. This can
significantly reduce the exposure to vibration over the total
working period.
Implement additional safety measures to protect the oper-
ator from the effects of vibration, such as servicing the
power tool and application tools, keeping the hands warm,
and organising workflows correctly.
Fitting
Fitting Protective Equipment
uPull the plug out of the socket before carrying out any
work on the power tool.
Note: If the grinding disc breaks during operation or the
holding fixtures on the protective guard/power tool become
damaged, the power tool must be sent to the after-sales ser-
vice immediately; see the "After-Sales Service and Applica-
tion Service" section for addresses.
Protective guard for grinding
Place the protective guard
(6) onto the holder on the
power tool until the coding
cams of the protective guard
are aligned with the holder.
When doing so, press and
hold the unlocking lever (1).
Press the protective guard
(6) onto the spindle collar un-
til the shoulder of the pro-
tective guard is sitting on the
flange of the power tool and
rotate the protective guard
until it audibly clicks into
place.
Adjust the position of the protective guard (6) to meet the
requirements of the operation. To do this, push the unlock-
ing lever (1) upward and rotate the protective guard (6) into
the required position.
uAlways position the protective guard(6) such that the
two cams on the unlocking lever(1) engage in the
corresponding openings on the protective guard(6).
uAdjust the protective guard (6) such that sparking in
the direction of the operator is prevented.
uThe protective guard (6) must only be adjustable
while the unlocking lever (1) is actuated. Otherwise,
the power tool must not be used any more under any
circumstances and must be sent to the after-sales ser-
vice.
Note: The coding cams on the protective guard (6) ensure
that only a protective guard that is suitable for the power
tool can be fitted.
Protective guard for cutting
uAlways use the protective guard for cutting (8) when
cutting with bonded abrasives.
uProvide sufficient dust extraction when cutting stone.
The protective guard for cutting (8) is fitted in the same way
as the protective guard for grinding (6).
Extraction guard for cutting with a guide block
The extraction guard for cutting with a guide block (17) is fit-
ted in the same way as the protective guard for grinding (6).
Side handle
uDo not operate your power tool without the side
handle (5).
Screw the side handle (5) on the left or right of the machine
head depending on how your are working.
Hand guard
uAlways fit the hand guard (13) when working with the
cup brush/disc brush (14) or diamond core cutter (19).
Attach the hand guard (13) to the auxiliary handle (5).
Fitting and removing abrasive tools
Follow the special assembly instructions for
X-LOCK application tools.
uPull the plug out of the socket before carrying out any
work on the power tool.
uDo not touch grinding and cutting discs until they have
cooled down. The discs can become very hot while work-
ing.
uOnly use original X-LOCK application tools that carry the
X-LOCK logo. A maintained clamping gauge of max.
1.6mm can only be guaranteed with original X-LOCK ap-
plication tools. A higher clamping gauge can lead to insec-
ure clamping, potentially causing the clamp tool to come
loose.
uX-LOCK application tools do not need additional clamping
flanges or support flanges.
uMake sure that the application tool and the holder are not
deformed and are free from dirt and particles.
Pay attention to the dimensions of the abrasive tools.
Make sure that both X-LOCK catches are open (see figure
below) before fitting the X-LOCK application tool.
If necessary, clean the area between the two X-LOCK
catches.
Bosch Power Tools 1 609 92A 6KD | (01.06.2021)
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch GWX 750-125 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info