52
Performance Data Sheet
Model 9000 7775078
Use Replacement Cartridge 9000 674655.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit
for water leaving the system as specified in NSF/ANSI Standard 42 and Standard 53.
* Based on the use of Cryptosporidium parvum oocysts
It is essential that the manufacturer’s recommended installation,
maintenance and filter replacement requirements be carried out for the
product to perform as advertised. See Installation Manual for Warranty
information.
Note: While the testing was performed under standard laboratory
conditions, actual performance may vary.
Replacement Cartridge: 9000 674655. For estimated costs of
replacement elements please contact your local dealer or
call 1-800-578-6890.
m Warning
To reduce the risk associated with ingestion of contaminants:
Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before and after the system.
Systems certified for cyst reduction may be used on disinfected
water that may contain filterable cysts.
EPA Establishment Number 10350-MN-005
m Caution
To reduce the risk associated with property damage due to water
leakage:
Read and follow Use Instructions before installation and use of this
system.
Installation and use MUST comply with all state and local plumbing
codes.
Do not install if water pressure exceeds 120 psi (827 kPa). If your
water pressure exceeds 80 psi, you must install a pressure limiting
valve. Contact a plumbing professional if you are uncertain how to
check your water pressure.
Do not install where water hammer conditions may occur. If water
hammer conditions exist you must install a water hammer arrester.
Contact a plumbing professional if you are uncertain how to check
for this condition.
Do not install on hot water supply lines. The maximum operating
water temperature of this filter system is 100 °F (38 °C).
Protect filter from freezing. Drain filter when temperatures drop
below 33 °F (0.6 °C).
The disposable filter cartridge must be replaced every 6 months, at
the rated capacity or if a noticeable reduction in flow rate occurs.
System tested and certified by NSF International against NSF/ANSI Standard 42 and Standard 53 for the reduction of
the claims specified on the Performance Data Sheet.
Capacity 739.68 Gallons (2800 Liters)
Contaminant Reduction Determined by NSF testing.
Contaminant
Reduction
Average
Influent
NSF specified
Challenge
Concentration
Avg %
Reduction
Average Product
Water
Concentration
Max
Permissible
Product Water
Concentration
NSF
Reduction
Requirements
NSF Test
Report
Chlorine Taste and
Odor
2,1 mg/l 2,0 mg/l ± 10 % 97,6 % 0,05 mg/l N/A 50 % J-00121313
Nominal
Particulate
Class I, 0,5 to <
1,0 μm
9.100.000
particles/ml
Mind. 10.000
particles/ml
98,8 % 111.817
particles/ml
N/A 85 % J-00099871
Cyst* 170.00 cysts/l Minimum
50.000 cysts/l
99,99 % 0,001 cyst/l N/A 99,95 % J-00109715
Turbidity 11 NTU 11 ± 1 NTU 98,1 % < 1 NTU 0,5 NTU 95,5 % J-00099885
Application Guidelines/Water Supply Parameters
Service Flow 0,75 gpm (2,83 lpm)
Water Supply Potable Water
Water Pressure 30 - 120 psi (207 - 827 kPa)
Water Temperature 0,6 °C - 38 °C (33 °F - 100 °F)
3M is a trademark of 3M Company used under license.
NSF is a trademark of NSF International.
© 2013 3M Company. All rights reserved.
Manufactured by:
3M Purification Inc.
400 Research Parkway
Meriden, Ct 06450
USA
Tel. (800) 222-7880
(203) 237-5541
52

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch KAD90VI30 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info