660380
9
Zoom out
Zoom in
Vorherige Seite
1/24
Nächste Seite
EN
|
9
Bosch Security Systems | 18 August 2005
LTC 8016/90 | Instruction Manual | Installation
NOTE: The video signal and Bilinx control
data require unobstructed two-way
communication. Do not place active video
devices in the coax line, because it will block
the control data signals.
Passive devices, such as ground loop isolation
transformers or other devices specifically designed to
support Bilinx communication, can be placed in the
coax line. In some configurations, it may be possible
to connect an active device after the video passes
through the head-end control unit. For sample
applications, refer to the Typical Configuration Diagrams
Section found later in this manual.
When an operating camera is connected to the
Interface Unit, the video channel LED illuminates
GREEN to indicate the presence of an acceptable
video signal. As Bilinx control data is sent to or
received from Bilinx-enabled cameras, the respective
channel LED flashes accordingly.
4.4 Group ID Number
The rear panel of the Interface Unit contains a set of
3 rotary switches, as shown below. Use the straight
slot side of the supplied offset screwdriver to set the
switches to the necessary value.
These switches are used to identify the group of
cameras to be connected to the Interface Unit. Each
group consists of 16 cameras in consecutive order,
and the group must always end at an exact multiple
of 16. For example, the lowest camera group range
is from 1 to 16. The next group range is from
17 to 32, etc., up to the last group (camera range of
9985 to 9999). If multiple Interface Units are used in
the same system, each Group ID number must be
unique.
The following chart summarizes the supported switch
settings:
When the Interface Unit is connected to an Allegiant
system using the Allegiant data interface protocol,
the Group ID switches should always be set to
correspond to the physical camera numbers used in
the system. For control systems that use the biphase
data interface, the switches should be set to
correspond to the controller’s logical camera
configuration.
After a change is made in a large Allegiant system
with multiple Interface Units, 30 seconds may be
required before the new settings take effect in all
Interface Units.
Setting 900 is reserved for factory use. If the Interface
Unit is inadvertently set to this value for more than
5 seconds before being set to its correct value, a
power off/on may be required for the unit to return
to its normal operating mode.
Select the step below that applies to your specific
system configuration.
BOSCH
POWER / DATA
Allegiant Bilinx Data Interface
Interface
Data
LTC 8016/90
Video + Data
NVT-211 or
NVT-213A Baluns
(Sold separately)
LTC 4631
F/O Module
Fiber Cable Length
600 m ( 2000 ft) max
Typical CAT-5
UTP Cable
225 m (750 ft)
max
LTC 4630
F/O Module
Coax
Coax
Bilinx-enabled
AutoDomes
Allegiant or Biphase
Control System
Switch Setting Use
001 to 625 Valid switch settings used for Allegiant and biphase
controller interfaces
901 to 931 Settings used in Allegiant interface mode to
terminate RS-485 data line
000 Reserved; setting is used during firmware upgrades
900 Reserved; setting is used by the factory
GROUP ID
0
2
6
4
8
0
2
6
4
8
0
2
6
4
8
Figure 2 Interface Unit Used with Other Video
Transmission Technologies
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch LTC8016 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info