Anti-seize protection:
The connected pump is monitored and exercised for a
short while after 24 hours of non-activity. This
prevents the pump from seizing.
The connected mixing valve actuator is monitored and
run automatically for a short period after 24 hours of
non-activity. This prevents the mixer from seizing up.
A maximum of 6 MM100 modules are permitted in one system
irrespective of the number of other BUS nodes.
As delivered, the coding card is in position 0. The module will
only be registered in the user interface if the coding card is in a
valid position for the heating circuit or cylinder primary circuit
(usually behind the low loss header).
A system schematic with 3 heating circuits with mixing valves,
one heating circuit without mixing valve and one primary
cylinder circuit is shown in Fig. 24 on page 103. A further
example with 3 or more heating circuits and 2 primary cylinder
circuits is shown in Fig. 27 on page 106.
2.1 Important notices on usage
The module communicates via an EMS 2/EMS plus interface
with other EMS 2/EMS-plus-enabled BUS nodes, such as
Greenstar boilers.
The module must only be connected to user interfaces with
the EMS 2/EMS plus (Energy Management System) BUS
interface.
The functional scope depends on the user interface
installed. Detailed information about user interfaces can be
found in the catalogue and technical guides and on the
manufacturer's website.
The installation space must be suitable for the IP rating
stated in the module specification.
2.2 Standard delivery
Fig. 1, page 91:
[1] Module
[2] Jumper for connection to MC1 if there is no temperature
switch in the assigned heating circuit (without mixer)
[3] Bag with strain relief
[4] Installation set flow temperature sensor
[5] Installation instructions
2.3 Technical data
The design and operation of this product comply
with European Directives and the supplementary
national requirements. Its conformity is
demonstrated by the CE marking. You can ask for a copy of the
declaration of conformity for this product. For this see the
contact address on the back cover of these instructions.
WARNING: Risk of scalding!
If DHW temperatures above 60 °C are set
or thermal disinfection is switched on, a
mixing valve must be installed at the DHW
outlet or at the DHW draw off points.
NOTICE: Floor damage!
Underfloor heating systems must only be
operated with an additional temperature
limiter (MC1 connection).
Technical data
Dimensions (W×H×D) 151×184×61mm (further
dimensions Fig. 2, page 91)
Maximum conductor
cross-section
230 V terminal
•Extra-low voltage
terminal
•2.5mm
2
•1.5mm
2
Rated voltages
•BUS
Module power supply
•User interface
•Pump and mixer
15 V DC (reverse-polarity-
protected)
230 V AC, 50 Hz
15 V DC (reverse-polarity-
protected)
230 V AC, 50 Hz
Circuit breaker 230 V, 5 AT
BUS interface EMS 2/EMS plus
Power consumption on
standby
<1W
Maximum output
Per connection (PC1
Pump Connection)
Per connection
(VC1 Mixing Valve
Connection)
400 W (high-efficiency
pumps permissible;
max. 40 A/s)
•100W
Temperature sensor
capturing range
lower fault limit
•display range
upper fault limit
•< 10°C
•0-100°C
> 125 °C
Table 3
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

bosch-mm-100

Suche zurücksetzen

  • Der Brenner arbeitet nicht mehr und die Kontrollanzeige blinkt rot, was ist zu tun? Eingereicht am 20-2-2021 16:13

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch MM 100 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Bosch MM 100

Bosch MM 100 Installationsanweisung - Englisch, Dänisch, Französisch, Polnisch, Türkisch, Schwedisch, Norwegisch, Finnisch - 116 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info