Rego 1000 – 6 721 831 662 (2021/03) en 13
6.4 Holiday
During holidays (absence), the heating can, for example, be kept at a
lower or higher level and hot water production can be switched off. Start
and Stop date, Room temperature and Block hot water production are
only displayed if the holiday function is activated.
3.1 Circuit 1 and hot water
3.1.1 Activate holiday function
3.1.2 Start date
3.1.3 Stop date
Set start and stop date for the desired period. Format yyyy-mm-dd.
The period starts and ends at 00:00. Both the start and end date are
included in the period.
Terminate the period prematurely by indicating No in menu item
3.1.1 Activate holiday function .
3.1.4 Room temperature
Set the room temperature that should apply to the circuit during the
period.
3.1.5 Copy to all heating circuits
3.1.6 Block hot water production
3.2 Circuit 2 (option)
Set the values in the same way as for 3.1 Circuit 1 and hot water .
3.3 Circuit 3 (option)
Set the values in the same way as for 3.1 Circuit 1 and hot water .
3.4 Circuit 4 (option)
Set the values in the same way as for 3.1 Circuit 1 and hot water .
6.5 Energy measurements
6.1 Generated energy
This displays 6.1 Generated energy in kWh divided into 6.1.1 Heating
and 6.1.3 Hot water.
6.2 Consumption electric additional heat
This displays 6.2 Consumption electric additional heat in kWh divided
into 6.2.1 Heating and 6.2.2 Hot water .
6.6 Timers
Timers are used by the control unit to count down the different time
dependent functions such as Extra hot water duration. At customer
level the following timers can be observed (only timers that are counting
are displayed):
6.7 External control
When an external input is connected, the control unit performs functions
which are set to Yes or is separated from 0 (Room temperature). When
the external input is no longer connected, the control unit returns to
normal mode. Only installed functions are displayed.
8.1 Heat pump 1
8.1.1 External input 1
8.1.1.9 Block compressor
8.1.1.11 Block additional heat
8.1.1.12 Block heating at tripped underfloor temperature limiter
8.1.1.13 Block heating
8.1.1.14 Room temperature
Set the room temperature that should apply in the event of enabled
external control.
Value > 0 °C enables the function.
The highest temperature is used if temperature changes have been set
for a certain circuit at several external inputs.
8.1.1.15 Block hot water production
8.1.2 External input 2
Set the values in the same way as for 8.1.1 External input 1 .
8.2 Heat pump 2
Set the values in the same way as for 8.1 Heat pump 1 .
8.5 External input circuit 2
8.5.2 Block heating at tripped underfloor temperature limiter
8.5.3 Block heating
8.5.6 Room temperature
8.6 External input circuit 3
Set the values in the same way as for 8.5 External input circuit 2 .
8.7 External input circuit 4
Set the values in the same way as for 8.5 External input circuit 2 .
6.8 General
Among other things, settings for date and time are available here.
12.1 Room sensor settings
12.1.1 Show outdoor temperature in room sensor
12.2 Set date
12.3 Set time
Check and change, if necessary, date and time. These are used by the
control unit to manage the different clock settings, e.g., holiday and
room temperature program.
12.4 Summer/winter time
Select if there should be automatic change over between summer
and winter time or not (dates according to EU standard).
12.6 Display contrast
If necessary, change the background light of the control panel.
12.7 Language
Change language, if desired.
6.9 Alarms
The different alarms that can occur are described in (Chapter 7).
Under 13 Alarms there is:
13.1 Information log
13.2 Delete information log
13.3 Alarm log
13.4 Delete alarm log
13.7 Alarm indication
13.1 Information log
Energy is measured per compressor; the calculated
results are added prior to being displayed.
Timer F value
7.1 Extra hot water 0h
7.3 Alarm mode delay 1h
7.5 Operating time for heating at hot water demand 20min
7.6 Hot water, operating time at heating demand 30min
7.7/7.8 Heat pump x timers
7.7.1/7.8.1 Compressor start delay 10min
7.11 Additional heat timers
7.11.1 Additional heat start delay 60min
7.11.2 Delay mixing valve control after additional heat start 20min
Table 8 Timers
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch Rego 1000 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info