11
TR5500T – 6 720 875 994 (2018/01)
heating” lights up. The function turns itself off again
automatically as soon as the configured temperature has been reached.
The LED “fast-heating” turns off.
The rest of the time, the device does not heat. If the “fast-heating”
button is activated, the device heats once to the configured
temperature. Afterwards, the device turns itself off automatically.
Boiler Mode
Connection without off-peak contact.
The device does not heat by default.
If the “fast-heating” button is activated, the device heats once
to the configured temperature. Afterwards, the device turns itself off
automatically.
Each further heating process must be started by pushing the button
“fast-heating” .
Electrical Connections
WARNING:
Danger of electric shock!
The power switch “S1” may only be activated in an unpowered state!
Remove lower cap by taking the screws out (Diagram 15, 15.1, 15.2,
15.3).
Lead cable through the cable gland and cord grip and connect,
then tighten the cable gland and cord grip (Diagrams 12- 13).
Check that the system is suitable for the maximum power absorbed
by the water heater (please refer to the data plate) and that the cross-
section of the electrical connection cables is suitable, and no less
than 1.5 mm2.
Operating mode
Set the power switch “S1” to the correct operating mode on
the electronic board.
Set the desired load according to the connection examples.
The power switch is set by the manufacturer in position 5.
Double power
Depending on the home installation, the following connection variations
are possible:
Refer to the connection types recommended for double power
Variant A, (Diagram 15):
If no low-tariff electricity is to be used, do not remove bridge between L1
and L1T.
Variant B, (Diagram 15.1)
Connect the output of the autotimer (delivered by the electricity
provider) with L1 and L1T.
Variant C, (Diagram 15.2)
Connect switched phase L1T (connection for low-tariff power) to L1T
terminal.
Variant D, (Diagram 15.3)
Connect switched phase L1 to terminal L1 and L1T.
Single power
Depending on the home installation, the following connection variations
are possible:
Refer to the connection types recommended for single power
Set power switch “S1” on the electronic board to positions 1 / 2 / 3 / 4
“single power”.
Boiler mode
Depending on the home installation, the following connection variations
are possible:
Refer to the connection types recommended for boiler switch.
Set power switch “S1” on the electronic board to positions 8 / 9 / 0
“boiler mode”.
Finally, separate the appropriate circuit diagram (E1/E2) and the
corresponding power-switch position “S1” from the enclosed adhesive
foil and adhere to the pad provided. Fill out the information decal about
the installed circuit and installed load and adhere to the outside of
the cover.
Initial Use
WARNING:
Important!
Fill the reservoir and flush it out until water discharges from all hot water
taps, otherwise the temperature sensor and retainer will be damaged
and require replacing.
Power Switch “S1” Mode of Operation
Double power switch positions 5 / 6 / 7
Single power switch positions 1 / 2 / 3 / 4
Boiler mode switch positions 8 / 9 / 0
According to the duration of the off-peak period of either 8 or 4 hours, and the associated loads
(refer to connection types), set the power switch “S1” to the correct positions 5 / 6 / 7,
of the double power set-up.
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

bosch-tronic-5500t

Suche zurücksetzen

  • Wie ist die stromsparendse Anwendung des Speichers? Eingereicht am 29-10-2024 21:24

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch Tronic 5500T wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info