697439
7
Zoom out
Zoom in
Vorherige Seite
1/12
Nächste Seite
Correcting burner faults | 7
6 720 812 901 (2014/10)Uni 3000 F
6 Correcting burner faults
The display shows heating system faults. Further information on the
fault displays can be found in the operating instructions of the relevant
control unit. In addition, burner faults are signalled by an indicator on the
burner.
Press burner reset button (see burner operating instructions).
If the burner still fails to start after three attempts, contact a suitably
qualified contractor.
7 Inspection and maintenance
7.1 What makes regular maintenance important?
Have your heating system regularly serviced:
to maintain a high level of efficiency and to operate the system
economically (low fuel consumption),
to achieve a high level of operational reliability,
to maintain the cleanest possible combustion.
7.2 When do you need to check the water pressure in your
heating system?
Recently added fill or top-up water loses much of its volume in the first
few days because it naturally releases gases. With new systems you
should therefore initially check the heating water pressure on a daily
basis, and then at gradually longer intervals.
Once the heating system is hardly losing any volume, check the
heating water pressure monthly.
A distinction is generally made between open vented and sealed
unvented systems. In practice, open vented systems are rarely installed
nowadays. We will therefore be using a sealed unvented heating system
to demonstrate how you can check the water pressure. All settings will
have already been made by the installation engineer when the system
was first commissioned.
NOTICE: Risk of system damage through frost.
When there is a frost, your heating system can freeze up
if it is shut down, e.g. through a fault shutdown.
If your heating system has been shut down for several
days due to a fault shutdown and there is a risk of
frost, drain the heating water at the drain & fill valve.
Also leave the air vent valve at the highest point in the
system open.
NOTICE: System damage due to the reset button being
pressed too frequently.
This can damage the burner ignition transformer.
Press the reset button no more than three times in a
row.
NOTICE: System damage through absence of or faulty
cleaning and maintenance.
Have the heating system inspected and cleaned by a
contractor annually. Check that the complete heating
system operates correctly.
Immediately correct all faults to prevent system
damage.
We recommend you enter a contract covering an
annual inspection and service subject to demand.
Annual inspection and service are part of the warranty
terms and conditions.
Use only genuine spare parts from the manufacturer.
Spare parts can be ordered via spare parts merchants.
A spare parts list is available online (see last page for
details).
The fill and top-up water quality must comply with the
specifications in the operator's log supplied.
Air pockets may form in the heating system through the
fill or top-up water releasing gases.
Vent the heating system (e.g. bleeding the radiators).
If required, top up with water.
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch Uni 3000 F wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Bosch Uni 3000 F

Bosch Uni 3000 F Installationsanweisung - Englisch - 40 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info