697430
40
Zoom out
Zoom in
Vorherige Seite
1/48
Nächste Seite
Safety equipment
Uni Condens 8000 F – 6720867056 (2016/10)
40
13.2 Safety equipment in accordance with the EC-type
examination
The following pieces of equipment are components of the EC-type
examination. We therefore recommend that you purchase safety
equipment with the boiler.
The following safety equipment is included in the type examination of the
boiler:
Table 17 Approval designations of additional safety equipment in
accordance with BS EN 12828:2012
13.3 Requirements for alternative items of safety
equipment and other pieces of equipment
13.3.1 Safety valve requirements
The safety valve must be suitable for discharging domestic hot water
(e.g. via type-tested devices in accordance with TÜV.SV...DG/H, or if
applicable in accordance with BS 6644 or BS5410 part 2.
The pipework between the boiler and the safety valve must be
unrestricted. The pressure drop in the pipework between the boiler
and the safety valve must be kept to a minimum.
The safety valve must be able to safely discharge the rated output
during a full load with the anticipated overpressure.
The pressure drop of the discharge pipe must not exceed the nominal
pressure of the safety valve by more than 10 %.
The pressure relief valve must be installed accessibly on the heat
source or within close range in the flow pipe, without any barriers
between the heat source and the pressure relief valve.
If using different safety equipment to the type shown in tab. 17,
page 40, the following information must be observed without fail as
otherwise the type examination qualification of the boiler will be
invalidated.
13.3.2 High limit safety cut-out requirements
Devices which are suitable for responding must be used
(e.g. type-tested devices with the identification TÜV.STB ID... or
devices according to EN 60730-2-9 (device type 2) or EN 14597).
To adjust the higher limit safety cut-out, observe the instructions in
chapter 7.1, page 25.
Limiters with a time delay are not to be installed.
The limiter is generally installed with the sensor set in the designated
socket branch with a sensor pocket. The installation situation for
other appliances is yet to be established. The sensor pocket is
screwed in ex works.
13.3.3 Maximum pressure limiter requirements
Devices which are suitable for responding under increasing pressure
must be installed (e.g. type-tested devices with the TÜV.SDB...S... ID).
Observe information in chapter 8.4.1, page 33.
Limiters with a time delay are not to be installed.
The limiter sits on the boiler safety assembly, possible connection
with G ½".
13.3.4 Water level limiter as low water indicator requirements
Devices which are suitable for responding with a lack of water
must be installed (e.g. type-tested devices with the TÜV.HWB...
or TÜV.WB... ID).
The low water indicator is installed on the boiler;
possible connection G 2".
13.3.5 Burner requirements
Oil burner certified in accordance with EN 267.
Gas burner certified in accordance with EN 676.
Please observe EMC and Low Voltage Directives, and other relevant
European guidelines.
Observe information in chapter 4.2, page 13.
13.3.6 Boiler controller
Comply with EMC and Low Voltage Directive.
Observe information in chapter 7.1, page 25.
13.4 Connection of the boiler
Information and examples of the boiler connection can be found in the
technical guide.
13.5 Dirt traps
Deposits in the heating system can lead to local overheating, noise and
corrosion. Any resulting boiler damage falls outside the warranty
obligations.
To remove dirt and sludge deposits, flush the heating system thoroughly
before connecting a boiler to an existing system. In addition, we
recommend the installation of dirt traps or a sediment separator.
Dirt traps retain contaminants and thereby prevent faults in control
devices, pipework and boilers. Dirt traps must be installed near the
lowest point of the heating system in an easily accessible position. Clean
the dirt traps every time the heating system is serviced.
Safety component Make Verification of
suitability
Minimum pressure
limiter as low water
indicator
Sauter DSL 143 F001 TÜV ID …6022
Maximum pressure
limiter
Sauter DSH 143 F001 TÜV ID …6023
High limit safety cut-
out
Sauter: TUC 407
F001
TÜV ID: 0000046121
40

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch Uni Condens 8000 F wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Bosch Uni Condens 8000 F

Bosch Uni Condens 8000 F Bedienungsanleitung - Deutsch - 16 seiten

Bosch Uni Condens 8000 F Bedienungsanleitung - Englisch - 12 seiten

Bosch Uni Condens 8000 F Bedienungsanleitung - Holländisch - 12 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info