Mounting and Operation
Starting
Electrical Safety
Warning! Switch off, remove plug from mains
before adjusting, cleaning or if cable is cut,
damaged or entangled.
Your machine is double insulated for safety and requires no
earth connection. The operating voltage is 230 V AC, 50 Hz
(for non-EU countries 220 V, 240 V as applicable).
For increased electrical safety use a Residual Current Device
(RCD) with a tripping current of not more than 30 mA. Always
check your RCD every time you use it.
The supply cables must be inspected for signs of damage at
regular intervals and may only be used if in perfect condition.
If the replacement of the supply cord is necessary, this has to
be done by Bosch or an authorized Bosch service agent in or-
der to avoid a safety hazard.
Only use approved extension cables.
WARNING! Inadequate extension cables can
be dangerous. Extension cable, plug and sock-
et must be of watertight construction and in-
tended for outdoor use.
Extension cords, cables, leads, reels should only be used if
they comply with EN 61242/IEC 61242 or
IEC 60884-2-7.
If you want to use an extension cable when operating your
product, only the following cable dimensions should be used:
Nominal Conductor Area of 1.5mm
2
to a max. cable length
of 20m for a Cord Extension Set
The connections (plugs and sockets) should be kept dry and
off the ground.
It is recommended that this is accomplished by means of a
cord reel which keeps the socket at least 60 mm above the
ground.
Note: If an extension cable is used it must be earthed and con-
nected through the plug to the earth cable of your supply net-
work in accordance with prescribed safety regulations.
Refer to the instruction manual of the extension cord, lead,
reel manufacturer and your local wiring regulations.
If in doubt contact a qualified electrician or the nearest Bosch
Service Centre.
For products not sold in GB:
WARNING: For your safety, it is required that the plug at-
tached to the product is connected with the extension cord.
The coupling of the extension cord must be protected against
splash water, be made of rubber or coated with rubber. The
extension cord must be used with a cable strain relief.
Products sold in GB only: Your product is fitted with a
BS 1363/A approved electric plug with internal fuse
(ASTA approved to BS 1362).
If the plug is not suitable for your socket outlets, it should
be cut off and an appropriate plug fitted in its place by an
authorised customer service agent. The replacement plug
should have the same fuse rating as the original plug.
The severed plug must be disposed of to avoid a possible
shock hazard and should never be inserted into a mains
socket elsewhere.
Products sold in AUS and NZ only: Use a residual current
device (RCD) with a rated residual current of 30 mA or
less.
Operation
Starting
Attach water supply hose (not supplied) to the mains water
supply and machine.
Connect the product to the mains supply ensuring that the
mains switch is in the off position.
Open water tap.
Press the safety lock (back button on the gun handle) to re-
lease the trigger. Fully press the trigger until there is a con-
stant flow of water to clear the air from the machine and water
supply hose. Release trigger. Press the safety lock (front but-
ton on the gun handle).
Turn button on main switch. Point the power gun downwards.
Press the trigger safety lock to release the trigger. Fully press
the trigger.
Autostop function
The machine is designed to switch off the motor when the trig-
ger is released on the gun.
Action Figure Page
Delivery Scope
1 272
Fold down handle operation
2 273
Adjusting the Handle
3 273
Connecting to the water supply
4 274
Connecting/Disconnecting high
pressure gun to lance
5 274
Connecting high pressure water supply
hose/nozzle 6 275
Disconnecting high pressure water
supply hose/nozzle
7 275
Switching On and Off
8 276
Attaching Nozzles
Adjust water jet
9–10 277278
Connect detergent bottle
11 279
Clean nozzle
12 280
Clean the water filter
13 280
Hose into the hose holder
14 281
Storage
15 281
Gun/lance/nozzle is stored in action
16 281
Selecting Accessories
17 282
OBJ_BUCH-2981-002.book Page 16 Wednesday, April 26, 2017 3:49 PM
16

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch UniversalAquatak 130 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info