51
•
ELECTRICAL CONNECTION
Single-phase 20A Counter
220-240V~ 50Hz
Electrical outlet
2 prong receptacle
+ earth
CEI Standard 60083
220-240 V ~ Single-phase line
Power
supply cable
length 1.50 m
approx.
16A fuse or differential
circuit breaker
Electrical safety must be guaranteed by fitting
the appliance correctly. During fitting and
maintenance operations, the appliance must
be unplugged from the electrical grid; fuses
must be switched off or removed.
The electrical connections are made before
the appliance is installed in its housing.
Ensure that:
- the electrical installation has sufficient volt-
age,
- the electrical wires are in good condition,
- the diameter of the wires complies with the
installation requirements.
Your oven must be connected with a (stan-
dardised) power cable with 3 conductors of
1.5mm
2
(1 live + 1 neutral + earth) which must
be connected to a 220-240V~ single-phase
grid via the intermediary of a 1 live + 1 neutral
+ earth CEI 60083 standardised power socket
or via an all-pole cut-off device or in compli-
ance with the installation rules.
Warning
The safety wire (green-yellow)
is con-
nected to the appliance’s terminal and
must be connected to the earth terminal of
the electrical set-up.
In the case of connection to an electric wall
socket, it must remain accessible after instal-
lation.
The fuse in your set-up must be 16 amperes.
If the power cable is damaged, it must be re-
placed by a cable or a special kit available
from the manufacturer or its After-Sales Ser-
vice Department.
2 / INSTALLING YOUR APPLIANCE
EN