38
Installing your hob in all simplicity
Changing the type of gas supply (cont'd)
● Gas rating
Appliance designed for installation: LPG
SINGAPOUR -
CHINA - BEIJING - SHANGAI
Hourly input -see below: 28-30mbar
DOUBLE-CROWN BURNER FRONT LEFT
Indicator marked on injector 92
Nominal heat rating (kW) 3,50
FAST BURNER BACK RIGHT
Indicator marked on injector 78
Nominal heat rating (kW) 2,35
EXTRA FAST BURNER FRONT LEFT
Indicator marked on injector 88
Nominal heat rating (kW) 3,10
SEMI-FAST BURNER BACK LEFT
Indicator marked on injector 62
Nominal heat rating (kW) 1,45
AUXILIARY BURNER FRONT RIGHT
Indicator marked on injector 45
Nominal heat rating (kW) 0,750
4 DOUBLE-CROWN RING GAS HOB
Total nominal heat rating (kW) 8,05
60
CM HOB 4 GAS RINGS WITH LARGE HIGH-SPEED RING
Total nominal heat rating (kW) 7,65
60 CM HOB 3+1 1500 W ELECTRIC HOTPLATE
Total nominal heat rating (kW) 6,20
FR - GR - GB - PT FR FR
Appliance designed for installation: Butane Propane Natural Natural Air-
FR ....................................Cat : III1C2E+3+ gas gas propane
GB - GR - PT ....................Cat : II2H3+ Air-
G30 G31 G20 G25 butane
G130
Hourly input -see below at 15°C at 1013 mbar 28-30mbar 37 mbar 20 mbar 25 mbar 8 mbar
D
OUBLE -
CROWN BURNER FRONT LEFT
Indicator marked on injector 92 92 144 144 360
Nominal heat rating (kW) 3,50 3,50 3,80 3,80 3,60
Low heat rating (with/without security device) (kW) 1,450 1,550 1,300
Hourly output (g/h) 254 250
Hourly output (l/h) 362 421 503
F
AST BURNER BACK RIGHT
Indicator marked on injector 78 78 121 121 210
Nominal heat rating (kW) 2,35 2,35 2,35 2,35 2,40
Low heat rating (with/without security device) (kW) 0,830 0,870 0,650
Hourly output (g/h) 171 168
Hourly output (l/h) 224 260 336
E
XTRA FAST BURNER FRONT LEFT
Indicator marked on injector 88 88 137 137 298
Nominal heat rating (kW) 3,10 3,10 3,20 3,20 3,10
Low heat rating (with/without security device) (kW) 0,830 0,870 0,780
Hourly output (g/h) 225 221
Hourly output (l/h) 305 354 434
S
EMI-FAST BURNER BACK LEFT
Indicator marked on injector 62 62 94 94 165
Nominal heat rating (kW) 1,45 1,45 1,50 1,50 1,50
Low heat rating (with/without security device) (kW) 0,620 0,615 0,550
Hourly output (g/h) 105 104
Hourly output (l/h) 143 166 210
A
UXILIARY BURNER FRONT RIGHT
Indicator marked on injector 45 45 63 63 122
Nominal heat rating (kW) 0,750 0,750 0,850 0,850 0,850
Low heat rating (with/without security device) (kW) 0,300 0,350 0,350
Hourly output (g/h) 55 54
Hourly output (l/h) 81 94 119
4
DOUBLE -CROWN RING GAS HOB
Total nominal heat rating (kW) 8,05 8,05 8,50 8,50 8,35
Maximum output (g/h) 585 576
(l/h) 810 941 1168
60
CM HOB
4 GAS RINGS WITH LARGE HIGH-SPEED RING
Total nominal heat rating (kW) 7,65 7,65 7,90 7,90 7,85
Maximum output (g/h) 556 547
(l/h) 753 874 1099
60
CMHOB3+1 1500 W ELECTRIC HOTPLATE
Total nominal heat ratingl (kW) 6,20 6,20 6,40 6,40 6,35
Maximum output (g/h) 451 443
(l/h) 610 708 889