What to do if …..
Problem Reason Solution
Heart rate
symbol
Appears in the measurement
condition and ashes when
pulse is detected.
Measurement in progress, remain quiet.
Low battery
indicator
Appears when the battery
voltage is excessively low or the
positions of the batteries are
incorrect.
Replace all four batteries with new ones.
Insert the batteries in the correct
positions. Be aware of +/- positions.
Measuring
error
Appears when the accurate
blood pressure and pulse could
not be obtained.
Press start/stop” button again and
remeasure.
Check if cu is wrapped according
to instructions.
Check that there are no kinks in tube.
Check palm if exerting eort.
Check if talking or moving
during measurement.
Check if posture is correct.
E1 shows The cu is not secure Refasten the cu and then measure again.
E2 shows The cu is very tight Refasten the cu and then measure again.
E3 shows Over-pressure Relax for a moment and then measure again.
E4 shows The monitor detected motion
while measuring
Movement can aect the measurement.
Relax for a moment and then measure again.
Eexx shows Measure incorrectly Relax for a moment and then measure again.
Retake the measurement. If the problem
persists, contact the retailer or our customer
service department for further assistance.
Refer to the warranty for contact information
and return instructions.
Erasing data
Press and hold memory button
M
(2) for more than 5 seconds,
LCD will blink display dEL ALL”(if the slide switch is in User A
side, the user A icon will show ”) or dEL ALL”(if slide switch is in
User B side, the user B icon will show).
Press memory button
M
(2) again, LCD will display “---” to mean
all the stored data of corresponding user have been deleted.
Irregular heart beat detector (for BP6200 only)
The appearance of this symbol signies that a certain pulse irregularity was detected during the
measurement. Talking, moving, shaking or an irregular pulse during the measurement can result in the
appearance of this icon. Usually this is not a cause for concern, however if the symbol appears often,
we recommend you seek medical advice. The device does not replace a cardiac examination, but serve
to detect pulse irregularities at an early stage.
Low battery indicator
When the low battery indicator ashes on the display, it means the battery is low and the four
batteries need to be replaced with alkaline LR6 (AA) batteries.
** After replacing batteries, BPM will go into time-setting mode automatically and show the
last measurement time on screen. Please set the current date / time before taking the next
measurement to get correct average result.
Storage and cleaning
Always keep the unit in the carrying case after its use.
Do not put the item directly under the sunlight, in high temperature or humid and dusty places.
Do not store in extremely low (less than -20°C) or high (more than 60°C) temperature.
Use a piece of cloth with water or mild cleansing agent to clean the case and then use a piece of dry
cloth to wipe it dry. Use a piece of dry cloth to wipe the cu when it is dirty.
Do not use any strong cleansers to clean it.
When the unit is not to be used for a long time, remove the batteries.
(Batteries may leak or cause harm).
Calibration
This device was designed and manufactured for a long service life, however it is generally
recommended to have the device inspected once a year to ensure correct function and accuracy.
Please contact the authorised service centre located in your country. Note: The calibration checking
is not a free service. Please contact the Authorized Service Centre to get a quotation before you send
out the product.
This device is not intended as a substitute for regular check-ups by your doctor, please continue to
visit your doctor on a regular basis for a professional reading.
Production date is given by the LOT located in the back of the device. The rst 3 numeric digits
after the LOT No represents the day of the year of manufacture. The next 2 numeric digits represent
the last two numbers of the calendar year of manufacture and the letters at the end designate the
manufacturer of the product. E.g. LOT 15612VAL this product was made on the day 156, year 2012 at
manufacturer identier VAL.
A
A
P
MD
A
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

braun-exactfit-3

Suche zurücksetzen

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Braun ExactFit 3 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info