517806
9
Zoom out
Zoom in
Vorherige Seite
1/20
Nächste Seite
ECONOMY MODE
DRAIN MODE
Selecting the ECONOMY mode limits
the maximum available cooling or
ventilation and reduces the power
used by up to 20%. The ECONOMY
function can be used in either AUTO
MANUAL modes. To select this
mode press the button so that
ECONOMY appears on the display.
Pressing the button opens the
drain valve in the cooler and empties
the water in the tank. This will leave
the tank clean and dry and turn the
cooler off.
If the cooler has not been used for 3
days or 3 hours, depending on the
DIP switch setting - see page 10, the
tank will automatically be drained to
ensure the system remains clean.
or
MANUAL
COOL
PM
FAN
SPEED
ECONOMY
ILL1125-A
DRAIN TANK
ILL1107-A
PRE - COOL MODE
Your remote control is designed to
allow for the saturation of the
coolers cooling pads before the
fan is switched on. This function,
referred to as PRE-COOL mode,
is enabled at DIP switch D (refer
to page 10). Once it is enabled the
cooler, will
operate as follows:
(1)...... If the tank is empty the
drain system will be closed. The
tank will then be filled.
(2)...... After 60 seconds of the
tank filling with water, the pump
will turn on and saturate the filter
pads.
(3)...... After the pump has been
running for 3 minutes the fan will
start.
During this operation the word
PRE-COOL will be displayed on
the remote control’s screen.
NOTE: PRE-COOL mode will not
be activated if VENT is selected
on the remote control or the cooler
is used again shortly after having
been turned off.
when first switched on,
MANUAL
COOL
PM
FAN
SPEED
ECONOMY
ILL1142-A
PRE-COOL
®
8
Evaporative Cooler
WATER MANAGER
®
The Breezair remote control is
fitted with the WaterManager
feature which automatically
monitors the quality of the water
in the cooler.
The WaterManager drains the
existing water in the cooler to
allow it to be replaced with fresh
water, only when it is needed.
Therefore, you may notice your
cooler draining water
occasionally. How often the
WaterManager performs this
operation depends upon the
quality of the water supply and
the rate of evaporation.
In areas of poor water quality, the
WaterManager will operate more
often as it tries to maintain the
optimum water quality in the
cooler. This maximises the
cooling effect and life of the
cooling pads.
The remote control has a unique
feature attached to the
WaterManager that allows you to
specify either high or low salinity
settings. The low salinity setting
is used in specific circumstances
only. We recommend talking with
your dealer before adjusting this
setting.
®
®
®
®
®
®
The high salinity setting is designed to
operate the cooler at a maximum safe
salinity level to maintain a normal
working life. It also results in a
minimum usage of water .
NOTE: High salinity outlet water should
not be used on salt sensitive grass or
plants. It has a high salt content.
The current WaterManager setting is
displayed by holding down the
button and pressing the button. The
setting can be changed by holding
down the button and pressing
either the or button for HI
and LO respectively.
The factory default WaterManager
setting is HI. For areas operating with
bore water, DIP switch F should be
switched to off (see page 10). This will
disable the salinity measuring circuit
and simply drain water from the tank
every 65 minutes of operation.
®
®
.......
MANUAL
COOL
FAN
SPEED
ECONOMY
ILL1111-A
MANUAL
COOL
PM
FAN
SPEED
ECONOMY
ILL1110-A
SEELEY INTERNATIONAL OWNER’S MANUAL 9
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Breezair EX series wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info