next setting.
3. Repeat step 2 for setting hours, minutes, seconds, year, month, date,
hour offset, language and daylight saving time (DST).
NOTE!
1. The unit will automatically exit setting mode if no button was pressed
in 60 seconds.
2. The hour offset is for DCF and MSF version. Its range is between -23
and +23 hours.
3. The language options are English (EN), French (FR), German (DE),
Spanish (ES), and Italian (IT).
4. DST (Daylight Saving Time) feature is set to Auto (factory set). The
clock has been programmed to automatically switch when the daylight
saving time is in effect. User can set the DST to OFF to disable the
feature.
Disable / Enable RCC signal reception (Fig. 12)
1. Press and hold RCC button 8 seconds to disable the reception.
2. Press and hold RCC button 8 seconds to enable automatic RCC
reception.
Fig. 22
RCC signal on RCC signal off
ALARM CLOCK SETTING
Turn on/off alarm clock (and ice-alert function) (Fig. 13)
1. Press button to show the alarm time.
2. Press button twice to activate the alarm.
3. Press button three times to activate alarm with ice-alert function.
4. To disable the alarm, press button until the alarm icons disappear.
Fig. 23
Alarm off Alarm on Alarm and ice-alert on
NOTE!
1. Press SNOOZE/LIGHT button when alarm sounds to interrupt the
alarm. The alarm will then start again after 5 minutes.
2. Pres button when alarm sounds to deactivate the alarm until next
time.
Alarm time setting
1. Press and hold button for 2 seconds to enter alarm setting mode.
Hours will begin to flash.
2. Use or button to adjust the desired value and press button
to proceed to set minutes.
3. Repeat step 2 to set minutes, then press button to exit.
NOTE!
Press button twice when alarm time is being displayed will activate
the temperature-adjusted pre-alarm (ice-alert). The alarm will sound 30
minutes earlier if it detects outside temperature is below -3°C.
WEATHER FORECAST
The device contains sensitive pressure sensor built-in with sophisticated
and proven software that predicts weather for the next 12 hours.
sunny, clear slightly cloudy cloudy rainy rainy, stormy snowy
Fig. 24
NOTE!
1. The accuracy of a general pressure-based weather forecast is about
70% to 75%.
2. The weather forecast is meant for the next 12 hours, it may not
necessarily reflect the current situation.
3. The “Snowy” weather forecast is not based on the atmospheric
pressure, but based on the outdoor temperature. When the outdoor
temperature is below -3°C (26°F), the “Snowy” weather indicator will
be displayed on the LCD.
4. The icon will flash on the screen when the rainstorm comes.
BAROMETRIC / ATMOSPHERIC PRESSURE
Atmospheric Pressure is the pressure at any location of the Earth caused
by the weight of the column of air above it. One atmospheric pressure
refers to the average pressure and gradually decreases as altitude
increases. Meteorologists use barometers to measure atmospheric
pressure. Since variation in atmospheric pressure greatly affected by
weather, it is possible to forecast the weather by measuring the changes
in pressure.
Select display mode
1. Press and hold button for 2 seconds to enter atmospheric pressure
setting mode.
2. Use or button to select between absolute and relative
atmospheric pressure:
• ABSOLUTE the absolute atmospheric pressure of your location
• RELATIVE the relative atmospheric pressure based on the sea level
Set relative atmospheric pressure value
1. Get the atmospheric pressure data of the sea level (it is also the
relative atmospheric pressure data of your home area) through the local
weather service, internet and other channels.
2. Press and hold button for 2 seconds until ABSOLUTE or RELATIVE
flashes.
3. Press or button to switch to RELATIVE mode.
4. Press button again and the number for RELATIVE flashes.
5. Use or button to change the value.
6. Press button to save and exit the setting mode.
NOTE!
1. The default relative atmospheric pressure value is 1013 mb/hPa
(29.91 inHg), which refers to the average atmospheric pressure.
2. When you change the relative atmospheric pressure value, the weather
indicators will change along with it.
3. The built-in barometer can notice the environmental absolute
atmospheric pressure changes. Based on the data collected, it can
predict the weather conditions in the forthcoming 12 hours. Therefore,
the weather indicators will change according to the detected absolute
atmospheric pressure after you operate the clock for 1 hour.
4. The relative atmospheric pressure is based on the sea level, but it
will change with the absolute atmospheric pressure changes after
operating the clock for 1 hour.
Select barometer measurement unit
Press button several times until the desired measurement unit is
displayed: inHg, mmHg or hPa.
TEMPERATURE & HUMIDITY
Comfort Indication
The comfort indication is a pictorial indication based on indoor air
temperature and humidity in an attempt to determine comfort level.
Fig. 25
too cold, too dry comfortable too warm, too humid
HINWEIS!
1. Comfort indication can vary under the same temperature, depending
on the humidity.
2. There is no comfort Indication when temperature is below 0°C (32°F)
or over 60°C (140°F).
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bresser 7902510 Weather Center 5-in-1 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Bresser 7902510 Weather Center 5-in-1

Bresser 7902510 Weather Center 5-in-1 Bedienungsanleitung - Holländisch - 12 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info