533826
1
Zoom out
Zoom in
2726
2120 2928
2322 3130
2524 3332
3534
36
I + BUTTON
Switches to next mode in clockwise direction
Advances the value of a setting
Activates/deactivates RCC receiving
J BATTERY COMPARTMENTS
Accommodates 4 UM-3 or “AA” size 1.5V batteries
K DC JACK
Accommodates a plug of 7.5V 200mA transformer
A DISPLAY
Facilitates easy reading of weather forecast,
barometer, remote or indoors temperatures and
humidity, heat index, clock, sunrise and sunset
B SNOOZE/LIGHT BUTTON
Activates the backlight and snooze function
C ALARM/CHART BUTTON
Displays the alarm time and high low temperature
alarm
Press and hold to enter alarm/alert setup
Press and hold in Pressure and Weather Forecast
mode to display temperature and humidity bar-charts
D SET BUTTON
Rotates display for current mode
Press and hold to enter setup or change units
Confirmation for setting parameters
E MEM BUTTON
Shows records for moon phase, temperature, humidity
F HISTORY BUTTON
Shows history for sea-level pressure
G CHANNEL BUTTON
Changes temperature and humidity display to selected
channel
Press and hold to enable cycling display of channel
temperature and humidity
H - BUTTON
Switches to next mode in anti-clockwise direction
Decreases the value of a setting
Activates thermo-hygro receiving
immediate search. If the temperature or humidity goes
above or below than the measuring range of the main
unit or the remote units (stated in specification), the
display will show [ ] or [HHH] or [LLL] respectively.
Press CHANNELcan change to desired channel.
Hold CHANNELfor 2 seconds can enter auto
scroll mode.
HOW TO READ THE KINETIC WAVE DISPLAY
The kinetic wave display shows the signal receiving
status of the main unit. There are three possible forms:
TEMPERATURE AND HUMIDITY TREND
The trend indicator shows the trend of temperatures and
humidity collected at that particular remote sight.
Three trends: rising, steady, and falling will be shown.
LOW BATTERY WARNING
When it is time to replace batteries for the remote sensor,
the respective low-battery indicator [ ] will show up
on the indoor or outdoor temperature & hygrometer
display.
SPECIFICATIONS
Temperature Measurement
Main unit
Proposed operating range: -5.0°C to +50.0°C
23.0°F to 122.0°F
Resolution: 0.1°C
0.2°F
Remote thermo-hygro unit
Proposed operating range: -20.0°C to +50.0°C
-4.0°F to 122.0°F
Resolution: 0.1°C
0.2°F
Relative Humidity Measurement
Main unit
Measuring range: 25% to 95%
Resolution: 1%
Remote thermo-hygro unit
Measuring range: 25% to 95%
Resolution: 1%
RF Transmission
Remote thermo-hygro
unit
Frequency: 433MHz
Maximum number of remote unit: 3
Range: Maximum 60 meters
(open area)
Cycle: 43 ~ 47 seconds
Barometric Pressure Measurement
Measuring range: 750 to 1100 hPa/mBar
at 25°C
(22.15 to 32.49 inHg)
Sampling cycle: 20 minutes
EC-DECLARATION OF CONFORMITY
Product : BF-7
This product contains the approved transmitter and
complies with the essential requirements of Article 3
of the R&TTE 1999/5/EC Directives, if used for its
intended use and that the following standard(s)
has/have been applied:
Efficient use of radio frequency spectrum
(Article 3.2 of the R&TTE Directive)
applied standard(s) EN 300 220:2000
Electromagnetic compatibility
(Article 3.1.b of the R&TTE Directive)
applied standard(s) EN 301 489-1,3:2000
Additional information:
The product is therefore conform with the Low Voltage
Directive 73/23/EC, the EMC Directive 89/336/EC and
R&TTE Directive 1999/5/EC (appendix II) and carries
the respective CE marking.
R&TTE Compliant Countries :
All EU countries
Calendar Clock
12/24 h display with hh : mm
Date Format : Day - Month or Month-Day.
Day of week selectable in 6 languages
(ENG, GER, FRE, ITA, SPA and DUT)
Dual 2-minute crescendo alarm with snooze
Pre-alarm for ice alert
Temperature alarm
Weather alarm for storm
Power
Main unit: 7.5V 200mA DC transformer
4 pcs UM-3 or “AA”
size 1.5V battery
Remote thermo-hygro unit: 2 pcs UM-3 or “AA”
size 1.5V battery
Weight
Main unit: 459g (Without battery)
Remote thermo-hygro unit: 62g (Without battery)
Dimension
Main unit: 218(L) x 122(H) x 30(D) mm
Remote thermo-hygro unit: 55.5(L) x 101(H) x 24(D) mm
WEATHER FORECAST
The unit is capable of detecting atmospheric pressure
changes. Based on collected data, it can predict the
weather for the forthcoming 12 to 24 hours.
SUNRISE AND SUNSET TIME
Calculates sunrise/sunset times with geographical
information (DST, zone time offset, latitude, longitude)
provided by user.
Over 133 preset cities can be selected for automatic
geographical information input.
HOW TO SET THE RADIO CONTROLLED
CLOCK
1. After the batteries are installed. The clock will
search the radio signal automatically. It takes about
3-10 minutes to finish this process.
2. If user wishes to disable the auto-reception feature,
holds “+” for 2 seconds to disable it.
3. To enable the auto-reception feature again, holds “+”
for 2 seconds again to force it receive and allow it
receive at desired time.
4. If the radio signal is received, the date & time will
be set automatically with radio control signal icon
[ ] turns on.
5. If the clock fails to receive the time signal, it will
be show as [ ] icon. Then user
can set the time
manually.
CALENDAR CLOCK DISPLAY MODES
The calendar is displayed in a day-month format. Each
press on the SETbutton will change the display
between clock with second, clock with day of week,
zone time with day of week and zone time with second.
HOW TO SET THE CLOCK MANUALLY
To set the clock manually, hold SETfor 2 seconds
will show the language. Press “+” or “-” to change it.
Press SETto confirm. Repeat the same procedure to
set °C/°F, year, month, date, date-month format,12/24
hour format, hour and minute. During the setting, press
and hold “+” or “-” will increase or decrease the value
rapidly.
For display language, you can choose among English
(ENG), German (GER), French (FRE), Italian (ITA),
Spanish (SPA) and Dutch (DUT) in that order. If there
is an item you do not wish to change, simply press
SETto bypass the item. When you finished the
change, press SETto exit. The display will return
to the clock mode.
HOW TO SET AND ARM THE ALARM
To set an alarm,
1. Press ALARM/CHARTonce to display alarm
time. If the alarm is disarmed, the time will be
displayed as [OFF].
2. Hold ALARM/CHARTfor two seconds.
The hour digits will blink.
3. Enter the hour using “+” or “-”.
4. Press ALARM/CHART”. The minute digits
will blink.
5. Enter the minutes using “+” or “-”.
6. Press ALARM/CHART”. The minute digits for
programmable snooze will blink.
7. Enter the minutes using “+” or “-”.
8. Press ALARM/CHARTto exit.
9. Repeat the same procedure to set single alarm.
The alarm [ ], [ ], [Pre-AL], [ ] (Higher
temperature limit) and [ ] (Lower temperature limit)
icons will be displayed indicating which alarm is armed.
You can also arm or disarm an alarm by pressing the
“+”, “-” button at alarm display mode.
Press SETto return to clock display mode.
Note: Weather alarm will on if higher or lower
temperature limit are set to on.
SNOOZE FEATURE
When the alarm sound is on, press the SNOOZE
key to enter snooze mode. After 8 minutes (Default
8 minutes, 1 to 15 minutes can be set), alarm sound
will be wake up automatically. The snooze cycle will
be restarted if you press the SNOOZEkey again.
If you leave
the alarm sound on for 2 minutes, it will
enter snooze mode automatically with maximum 3 times.
HOW TO STOP AN ALARM
Press ALARM/CHART” on the unit to stop an alarm.
ALARM FEATURE
* Weekday Alarm
The alarm sound will be activated and the icon will be
flashed on weekday when it is armed and the alarm
time is reach.
* Single Alarm
The alarm sound will be activated and the icon will be
flashed when it is armed and the alarm time is reach.
Once it finished, it will be disabled automatically.
* Pre-Alarm
The pre-alarm sound will be activated and the icon will
be flashed if the temperature of channel 1 is under or
equal two degree C.
It is programmable 15, 30, 45, 60 or 90 minutes earlier
than the weekday alarm or single alarm time.
* Temperature Alarm
The temperature alarm sound will be activated when
the temperature is out of the pre-set range.
* Weather Alarm
The weather alarm sound will be activated when it is
change to heavy rainy, heavy snowy and storm.
PRECAUTIONS
This product is engineered to give you years of
satisfactory service if you handle it carefully.
Here are a few precautions:
1. Do not immerse the unit in water.
2. Do not clean the unit with abrasive or corrosive
materials. They may scratch the plastic parts and
corrode the electronic circuit.
3. Do not subject the unit to excessive force, shock,
dust, temperature or humidity, which may result in
malfunction, shorter electronic life span, damaged
battery and distorted parts.
4. Do not tamper with the unit's internal components.
Doing so will invalidate the warranty on the unit
and may cause unnecessary damage. The unit
contains no user-serviceable parts.
5. Only use fresh batteries as specified in the user's
manual. Do not mix new and old batteries as the
old ones may leak.
6. Always read the user's manual thoroughly before
operating the unit.
HOW TO SET THE ZONE TIME
To set the zone time,
1. Press “SET” until at zone time display mode,
2. Hold “SET” for two seconds, the zone time offset
will be displayed.
3. Enter the offset using “+” or “-”.
4. Press “SET” to exit.
SUNRISE/SUNSET MODE
ACCESSING SUNRISE/SUNSET MODE
Press “+“ or “-“ until the sunrise and sunset icons
on the lower left of the display start flashing.
DISCONNECTED SIGNALS
If without obvious reasons the display of the outdoor
temperature
goes blank, Hold - for 2 seconds to
enforce an immediate search. If that fails, check:
1. The remote unit is still in place.
2. The batteries of both the remote unit and main unit.
Replace as necessary.
Note: When the temperature falls below freezing point,
the batteries of outdoor units will freeze, lowering their
voltage supply and the effective range.
3. The transmission is within range and path is clear of
obstacles and interference. Shorten the distance
when necessary.
TRANSMISSION COLLISION
Signals from other household devices, such as door bells,
home security systems and entry controls, may interfere
with those of this product and cause temporarily
reception failure. This is normal and does not affect the
general performance of the product. The transmission
and reception of temperature readings will resume once
the interference recedes.
NOTE:
1. The accuracy of a general pressure-based weather
forecast is about 70%.
2. The weather forecast may not reflect the current
situation necessarily.
3. The “Sunny” icon implies clear weather at night.
GETTING STARTED
SETTING UP THE REMOTE TEMP. AND RC CLOCK
a. Once the remote unit, are placed batteries, thermo-
hygro sensor will start transmitting temperature and
humidity readings at around 45 seconds intervals.
The main unit will also start searching for signals for
maximum 5 minutes once batteries are installed.
Upon successful reception, the outdoors temperatures
and humidity will be displayed .The main unit will
update its readings at about 45 seconds intervals
automatically.
b. If no signals are received, blanks [ ] will be
displayed. Hold - for 2 seconds to enforce
another search. This is useful in synchronizing the
transmission and reception of the remote and main
units.
c. When remote signal reception is finished, it will
automatically synchronize its current time and dated
when it is within the range of signal time. Repeat
this step whenever you find discrepancies between
the reading shown on the main unit and that on the
remote unit.
HOW TO CHECK REMOTE AND INDOOR
THERMO-HYGRO
The wave display on the outdoors temperature indicates
the reception of the remote unit is in good order. If no
readings are received from the remote units for more
than 5 minutes, blanks [ ] will be displayed until
further readings are successfully searched. Check the
remote unit is sound and secure. You can wait for a
little while or Hold - for 2 seconds to enforce an
NOTE: LED INDICATOR ON FRONT SIDE
Flashes once when the remote unit transmits a reading
Flashes twice when low battery is detected on sensor unit
(Model TS33C)
BEFORE YOU BEGIN
For best operation,
1. Insert batteries for remote units before doing so for
the main unit.
2. Position the remote unit and main unit within
effective transmission range, which, in usual
circumstances, is 60 meters. Note that the effective
range is vastly affected by the building materials and
where the main and remote units are positioned. Try
various set-ups for best result. Though the remote
units are weather proof, they should be placed away
from direct sunlight, rain or snow.
BATTERY INSTALLATION: REMOTE UNIT
1. Remove the screws on the battery compartment.
2. Select the channel.
3. Install 2 batteries (UM-3 or “AA” size 1.5V) strictly
according to the polarities shown.
4. Replace the battery compartment door and secure its
screws.
REMOTE THERMO-HYGRO
SENSOR
POWER INSTALLATION: MAIN UNIT
1. Plug a provided 7.5V 200mA transformer to the DC
jack of bottom side.
Or
2. Open the battery compartment door.
3. Install 4 batteries (UM-3 or “AA” size 1.5V) strictly
according to the polarities shown.
4. Replace the battery compartment door.
Note:
1. To provide reliable key operation under almost any
condition, the soft-touch buttons will self-calibrated in
1 second on power-up. Please leave your hands or
anything away from the soft-touch key when power-up.
2. The main unit is designed for transformer operated,
battery is only for back up purpose.
A BATTERY COMPARTMENT
Accommodates 2 UM-3 or “AA” size 1.5V batteries
B RESET BUTTON
Resetting of all functions after changing the channels
C UNIT BUTTON
Toggles the unit of temperature (if applicable)
D CHANNEL SELECTOR
Channel is to be selected before batteries are installed
E WALL MOUNT HOLE
For mounting the sensor on the wall
INTRODUCTION
Congratulations on your purchase of the BF-7.
Soft-touch button design provides you a novel key
interface and outlook design.
The basic package comes with 1 weather forecast
station and 1 remote thermo-hygrometer sensor.
The main unit is equipped with the built-in barometer
which enables to display the weather forecast,
barometer and altimeter.
The main unit is capable of keeping track temperature
and humidity of different sites. No wire installation is
required and operates at 433MHz.
Apart from temperature shows the indoor and outdoor
relative humidity and rates the comfort level. It also
retains the maximum and minimum relative humidity
readings. A remote thermo sensor is included with the
unit is able to receive and display readings from up to 3
remote sensors.
While the weather forecast part displays storm, alarm
will be activated.
MAIN UNIT
˚C
The unit is in
searching mode.
Temperature readings are
securely registered.
No signals.
Steady FallingRising
Arrow
indicator
Temperature
Humidity Trend
ATMOSPHERIC PRESSURE TREND
The atmospheric pressure indicator, in the weather
forecast window, uses arrows to indicate if the
atmospheric pressure is increasing, remaining stable,
or decreasing.
Steady FallingRising
Arrow
indicator
Pressure Trend
Symbol
Of Display
Forecast Sunny
Slightly
Cloudy
Cloudy Little Rainy
Symbol
Of Display
Forecast
Heavy
Rainy
Little
Snowy
Heavy
Snowy
Storm
CAUTION
- The content of this manual is subject to change without
further notice.
- Due to printing limitation, the displays shown in this
manual may differ from the actual display.
- The contents of this manual may not be reproduced
without the permission of the manufacturer.
TE657 NIL - MANUAL (2 ENG)
SIZE: W65 X H105 (mm)
BY ROSE KOON 08/08/07
FILM 08/08/07
(2 ENG)
A
B
C D E F G H I
J K
Cover Page 19 -
Back cover Page 36
USER’ S MANUA L
BF-7
Helmut Ebbert, Manager
Meade Instruments Europe GmbH & Co. KG
Germany
RESET
CHANN
EL
1 2 3
B
A
D
C
E
2
3

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

bresser-bf7

Suche zurücksetzen

  • Wie schalte ich von innen auf außen Temperaturen um Eingereicht am 23-3-2019 20:48

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bresser BF7 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Bresser BF7

Bresser BF7 Bedienungsanleitung - Deutsch - 1 seiten

Bresser BF7 Bedienungsanleitung - Holländisch - 14 seiten

Bresser BF7 Bedienungsanleitung - Französisch - 1 seiten

Bresser BF7 Bedienungsanleitung - Spanisch - 1 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info