7 Filter Capacity
Use of the PURITY Steam water fi lter system with integrated measuring and display unit or installa-
tion of the BRITA FlowMeter 100–700A is recommended for the precise, continuous control of the
degree of fi lter cartridge exhaustion (for article numbers see Chapter 13).
Capacity Table (in litres)
Carbonate
hardness
in °KH
PURITY 450 Steam PURITY 600 Steam PURITY 1200 Steam
Bypass position Bypass position Bypass position
0 1/2 3 0 1/2 3 0 1/2 3
4 5.633 6.134 6.760 8.833 9.619 10.600 16.530 17.999 19.836
5 5.633 6.134 6.760 8.833 9.619 10.600 16.530 17.999 19.836
6 5.633 6.134 6.760 8.833 9.619 10.600 16.530 17.999 19.836
7 4.829 5.258 5.794 7.571 8.244 9.086 14.169 15.428 17.002
8 4.225 4.601 5.070 6.625 7.214 7.950 12.398 13.500 14.877
9 3.756 4.089 4.507 5.889 6.412 7.067 11.020 12.000 13.224
10 3.380 3.680 4.056 5.300 5.771 6.360 9.918 10.800 11.902
11 3.073 3.346 3.687 4.818 5.246 5.782 9.016 9.818 10.820
12 2.817 3.067 3.380 4.417 4.809 5.300 8.265 9.000 9.918
13 2.600 2.831 3.120 4.077 4.439 4.892 7.629 8.307 9.155
14 2.414 2.629 2.897 3.786 4.122 4.543 7.084 7.714 8.501
15 2.253 2.454 2.704 3.533 3.847 4.240 6.612 7.200 7.934
16 2.113 2.300 2.535 3.313 3.607 3.975 6.199 6.750 7.439
17 1.988 2.165 2.386 3.118 3.395 3.741 5.834 6.353 7.001
18 1.878 2.045 2.253 2.944 3.206 3.533 5.510 6.000 6.612
19 1.779 1.937 2.135 2.789 3.037 3.347 5.220 5.684 6.264
20 1.690 1.840 2.028 2.650 2.886 3.180 4.959 5.400 5.951
21 1.610 1.753 1.931 2.524 2.748 3.029 4.723 5.143 5.667
23 1.470 1.600 1.763 2.304 2.509 2.765 4.312 4.695 5.175
25 1.352 1.472 1.622 2.120 2.308 2.544 3.967 4.320 4.761
28 1.207 1.314 1.449 1.893 2.061 2.271 3.542 3.857 4.251
31 1.090 1.187 1.308 1.710 1.862 2.052 3.199 3.484 3.839
35 966 1.052 1.159 1.514 1.649 1.817 2.834 3.086 3.400
The bypass position can be adjusted to the local water quality or the machine type.
The following recommendations for bypass settings apply by default:
Position 0: All devices in areas with an extremely high water hardness level (> KH = 22 °KH).
Position 1: Combi ovens and conventional ovens with direct injection system
Position 2: Combi ovens and conventional ovens with boiler system
Position 3: All devices in soft water areas (< KH = 7 °KH).
You can obtain individual recommendations from your BRITA contact.
Note: The stated capacities have been tested and calculated on the basis of common application
and machine conditions. External factors (such as fl uctuating crude water quality and/or machine
type) can cause deviations from this information.
8 Repair
Regularly check the fi lter system for leaks. Regularly check the hoses for kinks. Bent hoses must be
replaced.
The complete fi lter system must be replaced in rotation after a maximum of ten years.
The hoses must be replaced in rotation after a maximum of fi ve years.
33

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Brita PURITY 1200 Steam wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info