Filter system x* fl ush quantity
after 23 days stagnation
x** fl ush quantity
after 4 weeks stagnation
PURITY 450 6 litres 30 litres
PURITY 600 12 litres 60 litres
PURITY 1200 24 litres 120 litres
The fi lter system is not resistant to heavily concentrated cleaning agents (e.g. bleach, chlorin-
ated solvents, heavy oxidants) and must not come into contact with them.
The fi lter system must not be opened or dismantled during operation. The fi lter cartridge must
not be opened.
The pressure vessel and pressure vessel lid of the fi lter system are designed for a service life of
10 years (from the date of installation). They must be replaced after 10 years. The hoses must
be replaced in rotation after 5 years.
Production date
Production code sticker fi lter cartridge and box, example: B815002010
8 Production year, here: 2008
15 Production week, here: calendar week 15
002 Batch No. Filter medium, here the second batch fi lled in terms of quantity
010 Serial number of the fi lter cartridge, here the tenth cartridge from the second batch
Production code sticker connector head, example: 8252 H 11882
8 Production year, here: 2008
25 Production week, here: calendar week 25
2 Production day from Monday (1) to Friday (5), here: Tuesday
H H = with measuring and display unit
D = without measuring and display unit
11882 Serial identifi cation number
Production date pressure vessel and pressure vessel lid – example: 1108
11 Production month, here: November
08 Production year, here: 2008
3.5 Safety Assembly Instructions
The terminal device operated with the fi lter must be free of limescale prior to installation.
The fi lter system can also be operated downstream of water softening systems.
Protect the fi lter system from sunlight and mechanical damage. Do not assemble near sources
of heat and open fl ames.
A stop valve must be installed before the fi lter system intake hose.
If the water pressure is higher than 6.9 bar, a pressure reducer must be installed before the
lter system.
A non-return valve according to DIN EN 13959 tested by the DVGW has been factory installed
at the water intake of the fi lter head.
No copper pipes and no galvanised or nickel-plated pipes/connectors may be installed between
the water fi lter and the consumer. The use of BRITA hose sets is recommended here. When
choosing the material for parts that come into contact with water after the BRITA fi lter system
it must be remembered that, due to the process, decarbonised water contains free carbon diox-
ide.
All parts must be installed in accordance with the country-specifi c guidelines on the installation
of drinking water facilities.
The fi lter system must be operated within the stated ambient temperatures.
For erection and operation of the fi lter system, the BG rules “Working in Kitchens“ of the Spe-
cialist Committee “Foods“ of the BGZ (BGR111) must be observed.
22

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Brita PURITY 450 Quell ST wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info