4.1 Assembling the Filter Head, Water Connection
!
Caution: Ensure that the locking handle on the head is open.
A
B
Close water intake and switch off power supply to the terminal equipment.
Fit the wall mounting bracket
5
in the intended position.
!
Caution: During assembly, note the installation dimensions, bending radii of the
hoses and dimensions of the accessories (e.g. BRITA FlowMeter). The system can be
operated vertically and horizontally. When using the wall mounting bracket, only install in
a vertical position!
C
Fit the hoses to water inlet “IN”
4
and outlet “OUT”
3
of the fi lter head
1
. With
G3/8" connections use fl at seals and with John Guest connections use hoses with an
8 mm diameter. Both safety clips
11
need to be used with John Guest connections after
assembling the hose.
!
Caution: The max. tightening torque at the G3/8" connections must not exceed
14 Nm! Only hose connections with fl at seals may be used because hoses with conical
screw connections may damage the fi lter head connections, thereby invalidating any
guarantee claims! Only hoses that comply with DVGW-W 543 may be used for connec-
tion to the device. The use of BRITA hose sets (Chapter 10) is recommended.
D
Check by-pass setting
10
and adjust to local carbonate hardness, if necessary
(Chapter 4.2).
Note: The by-pass has been factory set at 30%.
Lock the fi lter head
1
in the wall mounting bracket
5
.
4.2 Setting By-Pass and Capacity
Identify the carbonate hardness of the local water using the BRITA carbonate hardness test
(Art. 710800). Alternatively, your local water supplier will provide information on carbonate
hardness.
Note: The water is not decarbonised when using PURITY C AC fi lter cartridges; the carbonate
hardness does not need to be determined.
Determine the by-pass setting and capacity according to the application and the carbonate hard-
ness identifi ed using the by-pass and capacity table (Chapter 6).
Then turn the by-pass setting
10
to the identifi ed value.
Note: Only PURITY C 0–70% fi lter heads have a variable by-pass setting. Installation of the
BRITA FlowMeter 10–100 A (Art. 298900) is recommended for the precise, continuous control
of the degree of fi lter cartridge exhaustion.
Note: All the intake water is fi ltered when using PURITY C AC fi lter cartridges. The fi lter car-
tridge can be used with both a variable and fi xed by-pass. The by-pass used where required in
the fi lter head is not taken into account.
4.3 Inserting the fi lter cartridge
E
F
Remove protective cap
7
.
Note the next exchange date in the date fi eld on the fi lter cartridge
6
.
Insert the fi lter cartridge
6
vertically in the fi lter head
1
.
!
Caution: The fi lter cartridge can only be inserted when the locking handle is open.
Make sure that the fi lter cartridge is positioned correctly.
Turn the locking handle
2
until you feel it engage.
4.4 Commissioning
G
H
Open the water intake and switch on the terminal equipment’s power supply.
Operate the fl ush valve
8
and fl ush the fi lter system until the fi ltered water runs clear
and without bubbles. At least two empty fi lter cartridge volumes must be fl ushed
( Chapter 9).
Note: When bleeding/ ushing, catch water emerging from the fl ush hose
9
in an
appropriate container.
Check system for any leaks.
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Brita PURITY C wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info