A non-return valve according to DIN EN 13959 tested by the DVGW has been factory installed
at the water intake of the fi lter head.
No copper pipes and no galvanised or nickel-plated pipes/connectors may be installed between
the water fi lter and the consumer. The use of BRITA hose sets is recommended here. When
choosing the material for parts that come into contact with water after the BRITA fi lter system
it must be remembered that, due to the process, decarbonised water contains free carbon diox-
ide.
All parts must be installed in accordance with the country-specifi c guidelines on the installation
of drinking water facilities.
For erection and operation of the fi lter system, the BG rules “Working in Kitchens“ of the Spe-
cialist Committee “Foods“ of the BGZ (BGR111) must be observed.
4 Installation
!
Caution: Prior to installation, read the Technical Data (Chapter 12) and the Operating and Safety
Information (Chapter 3). After the product has been stored and transported at temperatures below
0°C, it must be stored with the original packaging open for at least 24 hours before commissioning.
4.1 Delivery Scope
For installation of a PURITY Quell ST new fi lter, you need the packaging units pressure vessel
1
(incl. fi lter cartridge) and pressure vessel lid
3
.
Prior to installation, remove the entire delivery scope from the packaging and check that everything
is present:
1 x Pressure Vessel
1
1 x Pressure Vessel Lid
3
1 x Filter Cartridge
2
1 x Manual
1 x Carbonate Hardness Test
If part(s) of the delivery scope are missing, please contact your local BRITA Of ce.
4.2 Assembling the Pressure Vessel and the Pressure Vessel Lid
Stand with both feet on the kick loops
12
.
Lift the pressure vessel
1
and turn it clockwise until the mantle handles
16
are over the kick loops
12
.
Remove the transport protective cap
18
from the fi lter cartridge.
Check that the O-ring seal of the fi lter cartridge
2
is correctly seated in the
groove and also check for dirt and damage.
Note: lubricant at the factory.
Stand on the kick loops
12
with both feet and place the pressure vessel lid
3
on the pressure vessel
1
. The position of the arrow marking on the lid
handle
20
must match the “INSERT” groove.
Press the pressure vessel lid
3
down and turn clockwise until the lock
15
engages.
4.3 Assembly of Inlet and Outlet Hoses
Note: The inlet and outlet hoses are not included in the standard scope of delivery. The use of
BRITA hose sets is recommended (Chapter 13).
Fit inlet hose
6
at the inlet of the connector head
4
and outlet hose
10
at the outlet of the con-
nector head
4
.
Note: Inlet “IN” and outlet “OUT” of the connector head
4
are equipped with O-rings as
seals, therefore no additional fl at seals may be used here. Check that the O-rings are seated
correctly.
!
Caution: The max. tightening torque at the 1" and 3/4" connections must not exceed 15 Nm!
Only hose connections with fl at seals may be used. Hoses with conical screwed connections dam-
27

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Brita PURITY Quell ST wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info