Contents
3
We reserve the right to make any changes due to technical modifications!
Installation and Servicing Instructions Logamax plus GB142-24/30/45/60 • Version 12/2004
Buderus Hydronic Systems • http://www.buderus.net
1 Safety and general instructions . . . . . . . . . . 5
1.1 Designated use . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 Hazard definitions . . . . . . . . . . . . . . . . . . . . . . 5
1.3 The following instructions must be observed . . 5
1.4 Observe these instructions for heating
system water . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.5 Tools, materials and additional equipment . . . 6
1.6 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2 Regulations and guidelines . . . . . . . . . . . . . 7
3 Product description . . . . . . . . . . . . . . . . . . . . 8
4 Dimensions and connections . . . . . . . . . . . . 9
5 Packaging and transportation . . . . . . . . . . 11
5.1 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . 11
5.2 Transporting the appliance . . . . . . . . . . . . . . 11
6 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . 12
6.1 Requirements for the installation room . . . . . 12
6.2 Fitting the appliance. . . . . . . . . . . . . . . . . . . . 12
6.3 Making the gas connection . . . . . . . . . . . . . . 13
6.4 Fitting the heating circuit supply and
return pipes . . . . . . . . . . . . . . . . . . . . . . . . . . 14
6.5 Combustion Air and Ventilation Openings . . . 17
6.6 Installation of the flue gas adapter
(included in the scope of delivery) . . . . . . . . . 18
6.7 Installation of the Exhaust and
Air Intake system. . . . . . . . . . . . . . . . . . . . . . 18
7 Connecting the condensate water drain . . 23
8 Electrical connections. . . . . . . . . . . . . . . . . 24
8.1 External connection board connections. . . . . 24
9 Start-up procedure. . . . . . . . . . . . . . . . . . . . 27
9.1 Testing for gas leaks . . . . . . . . . . . . . . . . . . . 28
9.2 Filling the appliance . . . . . . . . . . . . . . . . . . . . 28
9.3 Filling the condensate trap. . . . . . . . . . . . . . . 29
9.4 Venting the gas supply valve . . . . . . . . . . . . . 29
9.5 Checking the combustion air/flue gas
connection . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
9.6 Checking the orrifices . . . . . . . . . . . . . . . . . . 30
9.7 Inlet gas pressure . . . . . . . . . . . . . . . . . . . . . 30
9.8 Checking and adjusting the gas/air ratio . . . . 31
9.9 Carrying out a tightness test in operating
conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
9.10 Measuring the carbon monoxide
content (CO) . . . . . . . . . . . . . . . . . . . . . . . . . 33
9.11 Function testing . . . . . . . . . . . . . . . . . . . . . . . 33
9.12 Measuring the ionization current . . . . . . . . . . 33
9.13 Installing the casing . . . . . . . . . . . . . . . . . . . . 35
9.14 Informing the owner, handing over the
technical documents . . . . . . . . . . . . . . . . . . . 35
10 BC10 basic controller . . . . . . . . . . . . . . . . . 36
10.1 Operating the BC10 basic controller . . . . . . . 36
10.1.1 Switching the heating system on and off . . . . 36
10.1.2 Displaying the operating conditions of
the burner and resetting the burner or
resetting burner faults . . . . . . . . . . . . . . . . . . 36
10.1.3 Displaying the heating system status
and/or faults. . . . . . . . . . . . . . . . . . . . . . . . . . 37
10.2 Carrying out additional tasks . . . . . . . . . . . . . 39
10.2.1 Carrying out a flue gas test . . . . . . . . . . . . . . 39
10.2.2 Selecting partial load operation
(e. g. during flue gas testing) . . . . . . . . . . . . . 39
10.2.3 Switching the heating system to
manual mode. . . . . . . . . . . . . . . . . . . . . . . . . 39
10.3 Configuring the appliance . . . . . . . . . . . . . . . 40
10.3.1 Adjusting the heating capacity. . . . . . . . . . . . 40
10.3.2 Setting the DHW temperature value . . . . . . . 41
10.3.3 Entering the heater water temperature . . . . . 41
10.3.4 Setting the pump post-purge period . . . . . . . 41
11 Shutting down the system . . . . . . . . . . . . . 43
11.1 Shut down the heating system using
the control unit. . . . . . . . . . . . . . . . . . . . . . . . 43
11.2 Shutting down the heating system
in the event of an emergency . . . . . . . . . . . . 43
12 Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . 44
12.1 Preparing the appliance for inspection . . . . . 44
12.2 Visual inspection for general signs of
corrosion . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
12.3 Internal tightness testing . . . . . . . . . . . . . . . . 45
12.4 Measuring the ionization current . . . . . . . . . . 45
12.5 Measuring the inlet gas pressure . . . . . . . . . 45
12.6 Checking and adjusting the gas/air ratio . . . . 45
12.7 Carrying out a gas tightness test in
operating conditions . . . . . . . . . . . . . . . . . . . 45
12.8 Measuring the carbon monoxide
content (CO) . . . . . . . . . . . . . . . . . . . . . . . . . 45
12.9 Carrying out a pressure test of the
heating system . . . . . . . . . . . . . . . . . . . . . . . 45
12.10 Checking the functioning and the safety
of the air intake and flue gas conduit. . . . . . . 45
12.11 Checking venting systems. . . . . . . . . . . . . . . 45
13 Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . 46
13.1 Cleaning the heat exchanger, burner
and condensate trap . . . . . . . . . . . . . . . . . . . 46
13.2 Checking and adjusting the gas/air-ratio . . . . 48
14 Servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
14.1 Checking the UBA3 fuse;
replace if necessary . . . . . . . . . . . . . . . . . . . 49
14.2 External connection board fuse . . . . . . . . . . . 49
14.3 Checking the fan unit; 120 VAC control . . . . 50
14.4 Checking the fan unit;
Supply cord (120 VAC) . . . . . . . . . . . . . . . . . 51
14.5 Checking the fan unit; Tacho cable . . . . . . . . 52
14.6 Replacing the fan unit . . . . . . . . . . . . . . . . . . 52
14.7 Checking the supply/return/safety/
hot-water temperature sensors . . . . . . . . . . . 53
14.8 Replacing the supply/return/safety sensors . 54
14.9 Checking the supply/return/
safety sensors cable . . . . . . . . . . . . . . . . . . . 55
14.10 Checking the hot surface ignitor; Control . . . 56
14.11 Checking the hot surface ignitor; resistance . 57
3

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

buderus-logamax-plus-gb142-45

Suche zurücksetzen

  • Heizung ausgefallen Display zeigte L3 214 an,ich habe die Heizung Aus und dann wieder ein geschaltet und sie lief wieder ist das ein Fehler? Eingereicht am 28-1-2019 16:31

    Antworten Frage melden

    • Hallo, Das Gebläse wird während der Sicherheitszeit abgeschaltet.

      Ursache 1: Beide Steckverbindungen am Gebläse kontrollieren.
      Ursache 2: Ansteuerung 230V des Gebläses prüfen, Versorgungskabel des Gebläses prüfen
      Ursache 3: Tachokabel des Gebläses auf Kabelbruch prüfen
      Ursache 4: Gebläsekabel mit Stecker und Gebläse prüfen

      Beantwortet 1-2-2019 07:53

      Finden Sie diese Antwort hilfreich? (107) Antwort melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Buderus Logamax plus GB142-45 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Buderus Logamax plus GB142-45

Buderus Logamax plus GB142-45 Bedienungsanleitung - Deutsch - 16 seiten

Buderus Logamax plus GB142-45 Bedienungsanleitung - Holländisch - 12 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info