Guideline to symbols and safety instructions
Logano G515 – 6 720 647 208 (2014/09) 3
8 Connecting the boiler on the flue gas side . . . . . . . . . . . . . . . 31
8.1 Fitting the vent pipe sealing collar (accessory) . . . . . . 31
8.2 Installing a flue gas temperature sensor (accessory) . 31
9 Installing the control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
9.1 Installing the control panel . . . . . . . . . . . . . . . . . . . . . . 32
9.2 Fitting temperature sensor assembly
and burner cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
10 Mounting the burner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
11 System start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
11.1 Filling the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
11.2 Commissioning the system . . . . . . . . . . . . . . . . . . . . . . 35
11.3 Start up the control panel . . . . . . . . . . . . . . . . . . . . . . . 35
11.4 Initial burner start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
11.5 Raising flue gas temperature . . . . . . . . . . . . . . . . . . . . . 36
11.5.1 Removing heat exchanger baffles . . . . . . . . . . . . . . . . . 36
11.5.2 Removing hot gas check plates . . . . . . . . . . . . . . . . . . . 36
11.5.3 Increasing the flue gas temperature slightly . . . . . . . . . 36
11.6 Commissioning log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
12 Shutting down the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
12.1 Shutting down the heating system
via the control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
12.2 Shutting down the system in an emergency . . . . . . . . . 38
13 System inspection and maintenance . . . . . . . . . . . . . . . . . . . 39
13.1 General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
13.2 Why is regular maintenance important? . . . . . . . . . . . . 39
13.3 Cleaning the boiler with cleaning brushes . . . . . . . . . . 39
13.4 Wet-cleaning the boiler . . . . . . . . . . . . . . . . . . . . . . . . . 41
13.5 Checking the operating pressure . . . . . . . . . . . . . . . . . 41
13.6 Filling with boiler water and purging the system . . . . . 41
13.7 Inspection and maintenance logs . . . . . . . . . . . . . . . . . 42
14 Troubleshooting burner faults . . . . . . . . . . . . . . . . . . . . . . . . . 45
15 Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
1 Guideline to symbols and safety instructions
1.1 Guideline to symbols
Warnings
Signal words at the beginning of a warning are used to indicate the type
and seriousness of the ensuing risk if measures for minimizing damage
are not taken.
NOTICE indicates that damage to property may occur.
CAUTION indicates possible minor to medium personal injury.
WARNING indicates possible severe personal injury.
DANGER indicates a potential for loss of life.
Important Information
Additional symbols
Warnings are indicated in the text by a warning triangle
and a gray background.
Important information neither indicating personal injury
nor damage to property are marked with this symbol.
They are separated by lines above and below the text.
Symbol Explanation
Sequence of steps
Cross-reference to other points in this document or to
other documents
Listing/list entry
Listing/list entry (2nd level)
Table 1
3

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

buderus-logano-g515

Suche zurücksetzen

  • I HAVE A FOUL NUMBER F 25 H. CAN YOU TELL ME WHAT THAT MEANS?
    MVH ARNE VEGUSDAL Eingereicht am 9-7-2019 09:30

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Buderus Logano G515 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Buderus Logano G515

Buderus Logano G515 Bedienungsanleitung - Englisch - 12 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info