784867
7
Zoom out
Zoom in
Vorherige Seite
1/40
Nächste Seite
AVOIDING THE RISK
OF ELECTROCUTION
DANGER - RISK
OF ELECTROCUTION
Initial safety warnings
The hot tub must be powered through
a residual current device (rCD) with a
current release not exceeding 30mA.
The devices and parts which contain
active parts – except those which are
powered from protective extralow
voltage not exceeding 12V – must be
inaccessible from the hot tub.
Connect only to a grounded source.
Do not bury the power cord. A buried
power cord may result in death, or seri-
ous personal injury due to electrocution
if direct burial-type cable is not used, or
if improper digging occurs.
WA R N I NG
• To reduce the risk of electrical shock, re-
place a damaged cord immediately. Fail-
ure to do so may result in death or serious
personal injury due to electrocution.
• Your hot tub must be connected to a
Ground Fault Circuit Interrupter (GFCI)
for user and equipment protection. To
ensure proper operation of this import-
ant safety device, test according to the
following instructions per electrical
configuration.
Cord-Connected 115 volt, 20 amp
models: The GFCI is located at the end
of the power cord. Before each use, with
the unit operating, push the TEST but-
ton. The unit should stop operating and
the GFCI power indicator will go out.
Wait 30 seconds and then reset the GFCI
by pushing the RESET button. The GFCI
power indicator will turn on, restoring
power to the hot tub. If the interrupter
does not perform in this manner, there
may be an electrical malfunction and
with it, the possibility of an electric
shock. Disconnect the power until the
problem has been corrected.
• 2x120 volt, permanently connected or
converted models:
• A ground terminal is provided on the
terminal block (TB-1, system ground ter-
minal) located inside the control box. To
reduce the risk of electric shock, connect
this terminal to the grounding terminal
of your electrical service or supply panel
with a continuous green, insulated cop-
per wire. The wire must be equivalent in
size to the circuit conductors supplying
the equipment. In addition, a bonding
terminal (pressure wire connector) is
provided on the outside of the control
box for bonding to local ground points.
To reduce the risk of electric shock, this
connector should be bonded with a No.
8 AWG (8.4 mm²) solid copper wire to
any metal ladders, water pipes, or other
metal within 5 feet (1.5 m) of the hot tub
to comply with local requirements. The
means of disconnection must be readily
accessible, but must be installed at least
5 feet (1.5 m) from the hot tub.
• Your hot tub is provided with a suitably
rated circuit breaker to open all un-
grounded supply conductors.
• Your hot tub uses ground fault circuit
interrupters in the electrical subpanel.
Before each use of the hot tub and with
the unit operating, push the TEST button
on each breaker. The switch should
click over to the “Trip” position. Wait
30 seconds and reset each GFCI breaker
by switching it completely off and then
completely on.
The switch should then stay on. If either
of the interrupters does not perform in this
manner, it is an indication of an electrical
malfunction and the possibility of an elec-
tric shock. Disconnect the power until the
fault has been identified and corrected.
SAFETY INSTRUCTIONS
7
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bueno Spa Chicago wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info