If there is a leak on your appliance (smell of gas), close the cylinder valve immediately and take it into a  ame free location where the leak
may be detected and stopped. If you wish to check for leaks on your appliance, do it outside. Do not try to detect leaks using a  ame; use
soapy water.
The correct way is to smear the joints e.g. where the stem  ts into the cylinder, with
soapy water.
If bubbles form, then there is a gas leak. Immediately turn off the gas supply by
closing the control valve on the gas container and then the appliance valve. Check
that all the connections are properly  tted. Re-check with soapy water.
If a gas leak persists, return the product to your CADAC dealer for inspection / repair.
Use Outdoors Only.
Fig. 3
Fig. 5
Fig. 1
Fig. 2
Seal
Cylinder Valve
Fit hose
clamp
here
RegulatorHose
3. Assembly Instructions
WARNING: The legs are spring loaded. Opening and closing of the legs must
be done in a controlled manner to avoid personal injury or damage to your
Camp Chef.
To open the legs, turn the unit upside-down and hold the legs down while lifting
each leg individually. You will hear a “click“ if the leg(s) has located correctly.
To fold the legs back, securely hold the leg and push the Leg Release Clip down.
Then push the legs in-ward to its closed position (Fig 6). This needs to be done
sequentially to optimise space. First the Right front leg (1), Then the
Left front leg (2), and lastly the rear Leg (3) (Fig 4b).
Before connecting the gas supply,  rstly check that the appliance valve is in the off
position by turning the control knob fully clockwise (See Fig. 2).
I 3B/P (30), I 3+ (28-30/37) and I 3B/P (37) Appliance categories: Fit the Valve
Tailpiece onto the Valve (Fig.5) by screwing it on in an anti-clockwise direction.
Push an 8mm inside diameter Hose onto the Valve Tailpiece until it is properly
seated. On the other end attach a suitable 30mbar low-pressure (I 3B/P (30) and
I 3+ (28-30/37) Butane con gurations) or 37mBar low-pressure regulator (I 3+
(28-30/37) Propane con guration), again making sure that the hose is well seated.
The hose used must comply with BS 3212 / SABS 1156-2 or equivalent.
I 3B/P (50) Appliance category: Screw a Hose with the correct threaded  ttings on
each end, onto the left hand ¼“BSP thread of the Valve. Attach a suitable 50mbar
low-pressure regulator on the other end of the hose. The hose used must comply
with DIN 4815 part 2 or equivalent.
Note: The hose and regulator are not supplied with the appliance. For details,
contact your local stockist.
The hose length should be no less than 800 mm and shall not exceed 1.5 m.
Check the expiry date on the hose and replace when necessary or when national
conditions require it. Do not twist or pinch
hose.
Your appliance is now ready for use.
OFF
Fig. 4a
Fig. 4b
Fig. 4a
Fig. 4b Fig. 4c
28-30 & 37mbar
ONLY
GB
503-0573 LEV12 (6530L0, 6530L1) Camp Chef LP - User Manual - (EU + SA).indd 2 15/08/2017 13:09:28
3

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Cadac 6530L1 - Camp Chef LP wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Cadac 6530L1 - Camp Chef LP

Cadac 6530L1 - Camp Chef LP Bedienungsanleitung - Deutsch - 7 seiten

Cadac 6530L1 - Camp Chef LP Bedienungsanleitung - Holländisch - 7 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info