GRACE - SPIRIT 5 - ATRIUM 5 - SOLO - ROXY - TABLA - MADISON 5
10
LEGEND Fig. 10
UInsulation
VPossible diameter increase
IInspection cap
SInspection access panel
PAir inlet
TTee fitting with inspection cap
ADistance from flammable material (smoke duct plate)
BMaximum 4 m
CMinimum 3° slope
DDistance from flammable material (appliance plate)
EReflux area
FAir ducting
The instructions in this chapter refer explicitly to the Italian installation regulation UNI 10683. In any case,
always observe the regulations in force in the country of installation.
6 INSTALLATION
6.1 INTRODUCTION
The heating system (generator + combustion air supply + combustion product expulsion system + any hydraulic/
aeraulic system) must be installed in compliance with the laws and regulations in force (*), and carried out by a
qualified technician, who must issue a declaration of conformity of the system to the system manager and shall
undertake full responsibility for final installation and consequent good operation of the product.
The manufacturer declines all responsibility in the event of installations that do not comply with the laws and regulations in force
and inappropriate use of the appliance.
In particular one must ensure that:
the environment is suitable for installing the appliance (floor load-bearing capacity, presence or possibility of creating an ade-
quate electrical/hydrauic/aeraulic system when required, volume compatible with the appliance characteristics, etc.);
the appliance is connected to a smoke expulsion system correctly sized according to EN 13384-1, which is resistant to soot fire
and which complies with the distances prescribed by the combustible materials indicated on the plate data;
there is a suitable combustion air flow to the appliance;
other combustion appliances or extraction devices installed do not cause a negative pressure of more than 4 Pa in the room
where the product is installed compared to the outside (only sealed appliances are allowed a maximum of 15 Pa of negative
pressure in the room).
(*) The national reference standard for the installation of domestic appliances is UNI 10683 (IT) - DTU NF 24.1 (FR) - DIN 18896 (DE) -
NBN B 61-002 (BE) - Real Decreto 1027/2007 (ES) - Paesi Bassi (NL) Bouwbesluit - Danmark (DK) BEK n° 541 del 27/04/2020.
In particular, it is recommended to strictly observe the safety distances from combustible materials to avoid se-
rious harm to people and to the integrity of the home.
Installation of the appliance must ensure easy access to service the appliance itself, the smoke channels and the flue.
Always maintain adequate distance and protection in order to prevent the product from coming into contact with water.
It is forbidden to install the stove in rooms with a fire hazard.
With the exception of sealed installations, it is also forbidden for liquid fuel appliances with continuous or inter-
mittent operation that draw the combustion air from the room they are installed in or B-type gas heating applian-
ces, with or without the production of domestic hot water, to coexist in the same room or in interconnecting rooms.
Sealed installation means that the product is certified as sealed and its installation (ducting
of the combustion air and connection to the chimney) is airtight with respect to the installa-
tion environment.
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Cadel ATRIUM 5 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Cadel ATRIUM 5

Cadel ATRIUM 5 Bedienungsanleitung - Englisch - 36 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info