CARINA - DORA
EN
LEGEND Fig. 8 page 9
1 ≥ 1,5 mt
2 ≥ 0,3 mt
3-3 Sectional view
4 Shield grid
5 Curve inlet to turn downwards
On all our stoves there is the possibility to draw the combustion air directly from outside. With this type of installation
the ventilation grid is no longer necessary, thus eliminating the ows of cold air that compromise the efciency
of the system.
Use a pipe with minimum Ø80 mm pipe and a maximum length of 2 metres; to connect the pipe see the back
of the stove.
During installation step is necessary to verify the minimum distances required for the combustible air inlet as
(for example) an open door or window causes a vortex which could remove the combustible air necessary
to the stove (see the underlying scheme).
On the external wall it is necessary to install a curve at 90° to protect the combustible air inow from wind
effects: turn the curve inlet downwards, see Fig. 8 page 9.
Endow the curve with an external shield grid against birds in such a way that it cannot be obstructed by any
object.
Check with your local authorities if exists any restrictive regulation regarding the combustible
air inlet: if present, they must be applied.
9.10 CHIMNEY FLUE CONNECTION
Your stove works through a natural draught. It is obligatory to check that all pipes are realized in compliance
with the following regulation on material selection: EN 1856-1, EN 1856-2 e UNI/TS 11278. All must be effected by
specialized personnel or companies as provided by UNI 10683:2012.
The connection between the appliance and the chimney ue should be short in order to favor the draught
and to avoid condensation in the pipes.
The fume conduit should be equivalent or longer than the outlet joint ones.
Some stove models are endowed with a lateral and/or back exhaust. Check that the unused exhaust is
sealed with the plug given with standard equipment.
SYSTEM TYPE Ø150 mm PIPE Ø240 mm PIPE
Minimum vertical length 1,5 mt 2 mt
Maximum length (with 1 union) 6,5 mt 10 mt
Maximum length (with 3 unions) 4,5 mt 8 mt
Maximum number of unions 3 3
Level section (minimum inclination 3%) 2 mt 2 mt
Installation at a height above 1200 m a.s.l. NO Obligatory
Use a specic plate pipe for stoves.
It is forbidden to use metal, bre cement or aluminium exible pipes.
For change of direction it is obligatory always to use a T-union (or a curve not with right angle) with inspection
plug which enables an easy periodic cleaning of the pipes.
Please assure you that after the cleaning the inspection plugs are sealed with its efcient gasket.
It is forbidden to connect more appliances to the same fume conduit.
It is forbidden to convey in the same fume conduit exhausts from overhanging cooker hoods.
It is forbidden to exhaust ue gases directly from the wall towards the outside and closed spaces also at open
top.
It is forbidden to connect any other appliance (wood stoves, cooker hoods, boilers, etc...).
The fume conduit must be placed at a distance of minimum 500 mm from ammable or heat-susceptible
components.
The fume conduit must be connected with stove exhaust in a xed and tight manner, and if required with the
insertion of a damper (see ).
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Cadel CARINA wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Cadel CARINA

Cadel CARINA Bedienungsanleitung - Französisch, Italienisch - 44 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info