13.6 PROGRAMMING EXAMPLES:
P1 P2
on off day on off day
08:00 12:00 mon 11:00 14:00 mon
Boiler on from 08:00 to 14:00
on off day on off day
08:00 11:00 mon 11:00 14:00 mon
Boiler on from 08:00 to 14:00
on off day on off day
17:00 24:00 mon 00:00 06:00 tue
Boiler on from 17:00 on monday to 06:00 on tuesday
13.7 NOTES FOR TIMER OPERATION
Start-up with the timer always takes place with the last temperature and ventilation settings (or with default
20°C and V3 settings in the event they have never been changed).
Start-up time ranges from 00:00 a 23:50
If the shutdown time is not already memorised, it proposes a start-up time in + 10 minutes.
A timer programme switches the boiler off at 24:00 of one day and another programme switches it on at 00:00
of the next day: the boiler stays on.
A programme proposes a start-up and shutdown in times included within another timer programme: if the
boiler is already on, start will not have any effect, while OFF will switch it off.
In the boiler on and timer active condition, press the OFF key and the boiler will switch off, it will switch on
automatically at the next time set on the timer.
In the boiler off and timer active condition, press the ON key and the boiler will switch on, it will switch off at
the time set on the active timer.
13.8 AUTO ECO MODE (SEE SECTION F-G SETTINGS MENU PAGE 30)
To activate the “Auto Eco” mode and adjust the time refer SETTINGS MENU page 30.
The possibility to adjust the “ECO shutdown t” comes from the need to ensure proper operation in the various
rooms the boiler can be installed in and prevent continuous shutdowns and start-ups in the event the temperature
is subject to sudden changes (air currents, poorly insulated rooms, etc.).
The ECO shutdown procedure is activated automatically when all the power demand devices involved in the
“system conguration” are satised: room probe/external thermostat, ow switch, puffer thermostat/ntc (10
ß3435) or boiler thermostat/ntc (10 ß3435). If all devices present are satised the “ECO shutdown t” time
decrease starts (by default 10 minutes, it can be changed within the “Settings menu”). During this stage the
panel displays ON with a small ame and alternately Chrono (of active) - Eco active. The minutes indicating the
countdown for the Eco Stop are shown at the top of the display. The ame goes into P1 and stays there until the
programmed “Eco shutdown t” time has elapsed and if the conditions are still satised, it goes into the shutdown
stage. The ECO switch off countdown resets if one of the devices boosts power again.
When switch off starts the panel displays: Off - Eco Active - small ashing ame.
Once the boiler has reached the off condition, the panel displays OFF-ECO with the extinguished ame symbol.
To restart from ECO the following conditions must be satised simultaneously:
Power demand
After 5 minutes from the beginning of shutdown.
TH2O < TSetH2O.
If the domestic hot water (DHW) demands power - if envisaged - the rst 5’ are ignored and the boiler restarts
as needed.
NOTE: In conguration 4 - 5 the Auto Eco mode is enabled automatically. Even when one sets the “summer”
function in conguration 2 - 3 it is enabled automatically. In the cases where it is designed to be active, it is not
possible to deactivate the mode.
13.9 SLEEP FUNCTION (MAIN MENU)
The sleep function is activated only when the boiler is switched on and allows to quickly set a time at which the
product must switch off.
To set the Sleep function act as follows:
40

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Cadel Idron 11 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Cadel Idron 11

Cadel Idron 11 Bedienungsanleitung und Installationsanweisung - Deutsch - 56 seiten

Cadel Idron 11 Bedienungsanleitung und Installationsanweisung - Holländisch - 56 seiten

Cadel Idron 11 Bedienungsanleitung und Installationsanweisung - Französisch - 56 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info